Owner`s manual
© 2010 Magnum Energy, Inc.Page 4
2.0 Introduction
2.1 MMP Series Overview
The MMP enclosures are available in four basic confi gurations; this section lists the four models
and the main components and features.
Individual Models:
MMP175-30D (Mini Magnum Panel, 175 ADC breaker, dual 30 AAC bypass/input breakers)
MMP175-60S (Mini Magnum Panel, 175 ADC breaker, single 60 AAC bypass/input breakers)
MMP250-30D (Mini Magnum Panel, 250 ADC breaker, dual 30 AAC bypass/input breakers)
MMP250-60S (Mini Magnum Panel, 250 ADC breaker, single 60 AAC bypass/input breakers)
Standard Features:
Enclosure is steel construction with durable white powder coat fi nish
Battery/inverter DC disconnect breaker (175 or 250 amp)
Inverter AC input overcurrent protection breakers
Pre-wired AC bypass switch for inverter isolation/battery maintenance
Front mount AC and DC breakers for quick and easy operation
AC and DC Ground screw type compression terminals (no lugs required)
500A/50mV DC shunt installed for easy connection to Battery Status monitor
Easy fi eld wiring with front mounted AC and DC input/output terminals
Enclosure and components are UL/CSA certifi ed and designated for indoor use
Confi gurations available for both single 120VAC and 120/240VAC systems
DC negative and ground busbars (negative can be isolated if PV-GFP device installed)
Battery positive busbar for DC loads and PV arrays included
Provides mounting for DIN rail or back-mounted DC load/disconnect breakers
Integrates directly with Magnum ME, MS, MS-PAE, and RD Series inverters
Top cover plate provided to allow other (non-Magnum) inverter installations
Knockouts for inverter and battery cables, PV in/out, DC breakers
Stud terminal available for large DC wire if used as system ground
Data cables with 300 volt rated insulation provided to allow 240 VAC inverter installations
Inverter hood provided to allow a Magnum inverter to be mounted vertically
Physical Features:
MMP Dimensions (H x W x D): 18” x 13” x 6.75” (45.7cm x 33cm x 17.1cm)
MMP Weight: 22.5 lbs. (10.2 kg)
Shipping Dimensions (H x W x D): 22” x 15” x 12.5” (56.9cm x 38.1cm x 31.8cm)
Shipping Weight: 31.5 lbs. (14.3 kg)
Optional Accessories/Components:
ME-RC – Remote Control with LCD display; allows inverter (or connected accessory) to be
confi gured and monitored, and maintain the critical settings in nonvolatile memory.
ME-ARC – Advanced Remote Control with LCD display; has all the features of the ME-RC remote,
but also confi gures the advanced features of the inverter (or any connected accessory).
ME-BMK-NS – Battery monitor; determines Battery State of Charge (DC shunt not included).
ME-AGS-N – Automatic Generator Start Controller (network version); automatically starts/
stops generators.
BP-MMP – Metal Backplate; for mounting the Magnum inverter and MMP enclosure, and is UPS
shippable. See Figure A-3 in Appendix A for more specifi c information.
DC Breakers – Space for up to four E-Frame/back mounted (1” width) or eight Q-Frame/DIN
rail mounted (1/2” width) DC breakers.
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•