2.0 Introduction
2.2 MMP External Components
As shown in Figure 2-1, the main components found on the outside of the MMP enclosure are:
1
Top Plate - The MMP enclosure is shipped with the top plate installed and is used either
as an upper conduit plate or a safety plate. If you are not installing a Magnum inverter,
then use this plate to route the AC and DC wiring from the MMP enclosure to the inverter.
If installing a Magnum inverter, then remove this plate and store it in a safe place; where
it can be easily retrieved.
If the Magnum inverter is ever removed for service while the AC bypass is used, then
this plate must be installed to prevent accidental access to live electrical circuits inside
the MMP enclosure. Four #10 x 3/8”, T25 Torx drive screws hold the top plate to the
enclosure.
2
Remote Blank Plate - This plate is removed when an optional ME-RC or ME-ARC Remote
control is installed.
3
Conduit Knockouts - Knockouts to allow metal and PVC conduits. For dimensions and
sizes see Figure 3-2.
4
Knockout Panels - Eight 1/2” rectangular knockout panels provided to install additional
DC circuit breakers.
5
Front Cover - The front cover is removed to allow access to the internal components. Four
#10 x 3/8”, T25 Torx drive screws are used to hold the front cover to the enclosure.
Figure 2-1, MMP Outside Components
5
3
1
2
4