Operator`s manual

2003 - Magnum Energy, Inc.
11
2. INSTALLATION
3. Installation
NOTE: Read all instructions and cautionary markings located at the beginning of this
manual and in the pre-installation section, before installing the inverter and
batteries.
CAUTION: Do not mount the inverter or the batteries near the vehicles
gasoline or propane fuel tanks.
Mount the inverter only on a non-combustable surfaces.
Maximum abient temperature MUST NOT exceed 113 °F (45 °C).
For Canadian installations, the inverters vents must face
downward.
Inverter Mounting
Position the inverter in the designated mounting location horizontally, vertically or
upside-down. Allow enough clearance to access the AC and DC connection points as
well as the inverters controls and status indicator. Also allow for air flow in to and
around the inverter, especially near the cooling fans (approximately 3).
Mark the mounting holes in the base of the inverters chassis. Remove the in-
verter and drill pilot holes into the mounting surface.
Secure the inverter to the mounting surface using appropriate screws and
lockwashers.
Remove the inverters AC access panel in accommodate the AC Input and Output
wiring and conduit.
Battery Installation
NOTE: To ensure the best performance from your inverter system, do not use old or
untested batteries. Batteries must be of the same size, type, rating and age.
NOTE: For optimum performance, Magnum Energy recommends using AGM
(absorbed glass mat) batteries such as Lifeline
TM
brand batteries.
NOTE: If using Flooded Lead Acid batteries, they must be mounted upright.
CAUTION: Install batteries in a well ventilated area. Batteries can produce explosive
gasses. For compartment or enclosure installations, always vent batteries
to the outside.
Place the batteries as close as practical to the inverter, preferably in an insulated
and ventilated enclosure. Allow adequate space above the batteries (+/- 6 above
the batteries) to access the terminals and vent caps (as applicable). Also allow at
least 1 of space between the batteries to provide good air flow. DO NOT mount the
batteries directly under the inverter.
Secure the batteries to the mounting surface with battery hold down clamps.