Operator`s manual

2003 - Magnum Energy, Inc.
27
2. INSTALLATION
5. Start-up and Test, continued
Configuring the Inverter
The ME Series inverter/charger must be configured for Low Battery Cutoff
(LBCO), Shore Power Current, Charger Amps, Battery Size and Battery Type. These
operational parameters must be configured using the optional remote control.
Refer to the ME Series Remote Control operators manual to configure the follow-
ing parameters:
Shore (5, 10, 15, 20, 30, 50)
AGS OFF
Enable
Meter DC
AC
Setup Search
LBCO
Battery Bank
Battery Type
Charge Rate
Contrast
Factory Reset
Tech Temps
Fault Record
The ME Series inverter/charger also allows you to select an equalize charge for
the batteries. Press and hold the Charger ON/OFF switch for 4 seconds. The Equal-
ize (EQ) function will be initiated (and the correct code will be sent to the remote.)
The EQ function automatically terminates after 4 hours of operation. You can also
manually stop the equalize mode by pressing and holding the Charger ON/OFF switch
while the inverter is in EQ mode.
Function Default
Search 5 watts
LBCO 11 VDC
Battery Bank 400 AHr
Battery Type Liquid Lead Acid
Charge Rate 100 %
Contrast 75 %
Table 5 - Factory Default Settings