Operator`s manual

2003 - Magnum Energy, Inc.
35
6. SPECIFICATIONS
ME Series Specifications
MODEL ME1512 ME2012 ME2512 ME3012
Input Voltage (nominal): 12 VDC 12 VDC 12 VDC 12 VDC
Input Voltage (range): 10.8-15.5 VDC 10.8-15.5 VDC 10.8-15.5 VDC 10.8-15.5 VDC
Power Rating @ 45°C: 1500 watts 2000 watts 2500 watts 3000 watts
Surge Rating: 3000 watts 4000 watts 5000 watts 6000 watts
Rated Power: 119 amps 158 amps 198 amps 238 amps
Full Voltage: 0.700 amps 0.900 amps 0.900 amps 0.900 amps
Search Mode: 0.045 amps 0.055 amps 0.030 amps 0.030 amps
Short Circuit: 238 amps 317 amps 396 amps 476 amps
Inverter Efficiency: 94% max 94% max 94% max 94% max
Charger Efficiency: 85% max 85% max 85% max 85% max
Charger (power factor): > 0.95 > 0.95 > 0.95 > 0.95
Charge Rate (adjustable): 0-70 amps 0-100 amps 0-120 amps 0-140 amps
Battery Protection (variable): 10-11.5 VDC 10-11.5 VDC 10-11.5 VDC 10-11.5 VDC
Unit Weight: 35lb (16kg) 38lb (17kg) 40lb (18kg) 45lb (20kg)
Common Specifications
Output Voltage: 120 VAC Frequency Regulation: 60 Hz ± .04%
Voltage Regulation (max): ±5% Voltage Regulation (typ): ±2.5%
Waveform: modified sine Power Factor: 0 to 1
Adjustable Load Sensing: 5 to 100 watts Automatic Transfer Relay: 30 amps at 120 VAC
Remote Control: optional 50 amps at 240 VAC
Charging Profiles: liquid lead acid, Four Stage Charging: bulk, absorb, float
AGM, and GEL and Battery Saver
TM
Forced Air Cooling: variable speed fan Temp Comp Probe: yes
DC Load Disconnect Sensing: on/off Remote Dry Contact: optional pigtail
(high/low DC signal) (inverter on/off)
Series Operation: 240 VAC (future)
Environmental Characteristics
Operating Ambient Temp: -4 °F to +120 °F (-20 °C to +50 °C)
Max Altitude (operating): 15,000 feet (4.57 km)
Dimensions (HxWxD): 13.75 x 12.65 x 8 (34.9 cm x 32.1 cm x 20.3 cm)
Mounting: shelf (top or bottom up) or bulkhead
Specifications @ 25 °C - Subject to change without notice