Setup
FAVS Menu Default Settings:
FAVS: F1 Search Watts – This is the F1 default (FAVS #1). Refer to the SETUP: 02A Search
Watts menu item on page 20 for information on how to adjust the Search Watts setting.
FAVS: F2 LBCO (Low Battery Cut Out) Setting – This is the F2 default (FAVS #2). Refer
to the SETUP: 02B LBCO Setting menu item on page 21 for information on how to adjust the
LBCO setting.
FAVS: F3 AC Input Amps – This is the F3 default (FAVS #3). Refer to the SETUP: 03A AC
Input Amps menu item on page 24 for information on how to adjust the AC Input setting.
FAVS: F4 Battery Type – This is the F4 default (FAVS #4). Refer to the SETUP: 03C Battery
Type menu item on page 26 for information on how to set the battery type.
FAVS: F5 Gen Control – This is the F5 default (FAVS #5). Refer to the CTRL: 03 Gen Control
menu on page 72 for information on how to use the Gen Control function.
Info: F5 Gen Control is a menu heading. It provides easy access to turn the generator
on and off. If another menu item is saved in the F5 location, the only way to bring Gen
Control back into the F5 location is to reset the remote to its factory defaults using the
TECH: 08 Load Defaults menu (page 39).
Rotary SELECT Knob
LCD
Display
FAVS Button
Float Charging
DC 13.34V + 0A
Figure 3-3, FAVS Button and Menus
Press to
edit setting
Press
FAVS
Rotate to desired
selection:
Top line shows current
FAVS menu and
position in FAVS menu.
Bottom line shows
current setting.
To select a FAVS
item
F1 Search Watts
5 Watts
F2 LBCO Setting
F3 AC Input
F4 Battery Type
F5 Gen Control
Note: These are default selections
that you can change.