ME-ARC Inverter Compatibility List

Magnum Energy, Inc. PN: 64-0030-030 Rev B Page 1 of 2
Inverter Compatibility Sheet for the ME-ARC with Revision 3.0/3.01
The ME-ARC has many advanced settings, and is designed to work with the advanced features in your Magnum
inverter and/or other Magnum devices (i.e., ME-AGS-N or ME-BMK). The ME-ARC communicates with your inverter
to allow these advanced features to be set up or enabled. However, when the ME-ARC is released with a new
software revision, some of the features and functionality in this remote may not be available in an inverter or
networked accessory that has an earlier software level. In this case, when the advanced setting is requested from
the ME-ARC to your inverter (or any other Magnum device networked with the inverter), this setting is not
recognized and will not function. Use the steps below to help you determine which ME-ARC (Revision 3.0/3.01)
menus/features are compatible with your inverter.
1. Go to: http://magnumenergy.com/inverter-compatibility/ to determine your inverter’s compatibility level
(L1, L2, L3 or L4).
2. Use the table below to determine which ME-ARC ‘Features/Settings’ you want to use and what inverter
compatibility level is required (see ‘Inverter Model/Level Required’).
3. If your inverter compatibility level is the same or greater than the ‘Inverter Model/Level Required’, then
your inverter can support the device setting/feature you want.
4. If your inverter does not have the required compatibility level for a feature/setting you want, contact
Magnum Energy to determine if there is a software upgrade option for your inverter.
Main Menu Menu Heading/Item
≥Level 1
≥Level 3 [1]
≥Level 3 [1][6]
≥Level 4
≥Level 1 [7]
01A DC Volts ≥Level 1
01B DC Amps ≥Level 1
01C Charge Time ≥Level 1
02A Output Volts ≥Level 4
02B Output Hz ≥Level 4
02C Load Amps ≥Level 4 [1][3]
02D Input Amps ≥Level 4 [1][3]
02E Inv/Chg Amps ≥Level 4 [1][3]
02F Input AC (AC1) [F] MSH Models only
02G Input AC2 [F] MSH-RE Models
03A AGS Status ≥Level 1
03B DC Volts-AGS ≥Level 1
03C Gen Run Time ≥Level 1
03D AGS Temp ≥Level 1
03E Since GenRun ≥Level 1
04A BMK Status ≥Level 1 [6]
04B SOC ≥Level 1 [6]
04C DC Volts-BMK ≥Level 1 [6]
04D DC Amps-BMK ≥Level 1 [6]
04E AH In/Out ≥Level 1 [6]
04F Reset AH Out ≥Level 1 [6]
04G Total AH Out ≥Level 1 [6]
04H Minimum VDC ≥Level 1 [6]
04I Maximum VDC ≥Level 1 [6]
01A Set Clock ≥Level 1
01B Contrast ≥Level 1
01C Backlight ≥Level 1
01D Power Save ≥Level 1
01E Temp Display ≥Level 1
02A Search Watts ≥Level 1
02B LBCO Setting ≥Level 2
02F Power Up Always [F] ≥Level 1
02E AC In - SOC [F]
Default
setting.
02 Invert Setup
02C AC In - Time
02D AC In - VDC
Inverter
Model/Level
Required.
03 Gen Control
Button
METER
Read only display
Read only display
SOC Connect [F]
Multi-Stage, Force Float, Restart Bulk
OFF, ON, AUTO
Read only display
Read only display
CTRL
01 DC Meters
01 ACIn Control
02 CHG Control [5]
02 AC Meters
[5]
03 AGS Meters
04 BMK Meters
01 Remote Setup
FEATURES/SETTINGS
Auto Connect
Selections/Adjustments Range
ME-ARC (REVISION 3.0/3.01) COMPATIBILITY MATRIX
SETUP
ON, OFF
Disconnect SOC= 21-100%
Read only display
Read only display
Read only display
Read only display
Read only display
Read only display
Read only display
Read only display
Read only display
Read only display
Read only display
Read only display
Read only display
Read only display
Read only display
Read only display
Read only display
Read only display
Read only display
Read only display
Time= 12:00A-12:00P
0-100%
0-100%
OFF, 1-60 Minutes
Fahrenheit, Celsius
OFF, 5-50 watts (1 watt increments)
9.0-12.2* VDC
Connect Time= 12:00A-12:00P
Disconnect Time= 12:00A-12:00P
Connect Volts= 9.0-15.9* (12V)
Disconnect Volts= 9.0-15.9* (12V)
Connect SOC= 20-98%
Always OFF
100%
50%
14.1
11.0
6:00P
6:00A
10.0 VDC
5 Watts
Fahrenheit
15 Minute
50%**
100%**
12:00A**
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
OFF**
Multi-Stage
Auto Connect
Read Only
Read Only
Read Only
Read Only
≥Level 3 [1]
≥Level 3 [1]
VDC Connect, Time Connect, AC-In Disabled