3.0 Setup
3.3.4 SETUP Menu
Pressing the SETUP menu button provides access to the menu items and
settings that allow the inverter/charger to be confi gured. Review each
menu item to determine if any setting requires adjustment to meet your
requirements.
• SETUP: 01 Search Watts – Allows you to turn off the Search Watts
feature, or to adjust the power level to determine when the inverter
leaves Search mode. If this feature is not needed, select Search=OFF.
When search is turned off, the inverter continuously provides full AC
voltage to the loads.
Default setting: Search = 5W
Range: OFF, 5-50 Watts (5 Watt increments)
• METER: 02 BM: SOC thru 06 BM: TECH – These menus allow the
optional ME-BMK (Magnum Energy’s Battery Monitor Kit)—if installed—
to be confi gured to your specifi c system preferences, and displays the
status of the battery system.
Info: Refer to Section 8.0 (in this manual) and to your ME-BMK/
BMK-NS Owner’s Manual (PN: 64-0013) for detailed information
on these menus and the Battery Monitor Kit.
from the inverter to run an AC load—either using the batteries in
Inverter mode, or from the AC input source in Standby mode. The
reading is negative (–) to indicate power is being returned to the inverter
through the AC output terminals—possible in an AC coupled installation.
(MS-PAE, MS-PE and MSH Series models only)
Input Amp: Displays the total AC amps being used by the inverter
for charging and for powering any connected load at the output of the
inverter. This reading is always displayed as a positive (+) number. (MS-
PAE, MS-PE and MSH Series models only)
Example: If the charger is using 20A from the AC source and the load
connected to the inverter output is using 10A, the combined load on
the incoming AC source is 30A. So, 30A is displayed as the input amps.
I/C Amps: Displays the inverter or charger amps. A negative (–) amps
reading indicates the inverter is powering the inverter loads and the
batteries are discharging (inverter amps). A positive (+) amps reading
indicates the inverter is using the AC input source to charge the batteries
(charger amps). (MS-PAE, MS-PE and MSH Series models only)
AC Input: Displays the RMS value of the AC voltage at the inverter’s
AC1/HOT IN 1 and NEUTRAL terminals. (MSH Models only)
AC2 Input: Displays the RMS value of the AC input voltage applied to
the inverter’s AC2 and NEUTRAL terminals. (MSH-RE Models only)
METER
Press
Status...
01 INV/CHG Meter
Display shows
menu item:
Status...
DC: ##.#V #A
Display shows
DC meter:
Press to select
Figure 3-5, METER: 01 INV/CHG Meter Display