7.0 Using an AGS Module
55 ©2013 Magnum Energy, Inc.
7.0 Using a ME-AGS-N Module
The ME-RC remote’s AGS menus under the AGS and TECH buttons allow
you to customize and monitor the operating parameters for your autostart/
autostop generator system. To help con gure and operate the AGS with your
ME-RC, refer to the mini index below to direct you to the appropriate section.
7.1 ME-AGS-N Setup page 55
7.2 ME-AGS-N Functional Tests page 59
7.3 ME-AGS-N Operation/Monitoring page 59
7.4 Enabling the ME-AGS-N page 62
7.5 Starting and Stopping the Generator page 62
7.6 ME-AGS-N Menu Map page 63
Inverting
DC 12.6V 5A
SHORE AGS METER SETUP TECH
AGS and TECH Buttons
Figure 7-1, ME-RC’s AGS Con guration Access Buttons
7.1 ME-AGS-N Setup
Press the AGS button on ME-RC remote (Figure 7-1), and then rotate
the SELECT knob to navigate to the AGS menus. These menus allow the
generator to be automatically started and stopped based on different
parameters. Using Table 7-1, determine the speci c autostart and autostop
condition with which you want the generator to be automatically controlled,
and then use that speci c menu setting to con gure the AGS.
Note: For information on using the AGS: 01 AGS Control, AGS: 02 AGS
Status, and AGS: 08 AGS TECH menus, refer to Section 7.3 “AGS Operation/
Monitoring”.
Table 7-1, ME-RC Autostart/Autostop Matrix
Autostart
Condition
See AGS Menu Autostop
Condition
See AGS Menu
Gen starts on high
temperature, or
04 Start Temp F
(page 56)
Gen stops after a
set time period, or
03 Run Time Hour
(page 56)
Gen starts on low
inverter battery
voltage
05 Start Volts
(page 57)
Gen stops at Quiet
Time
07 Quiet Time
(page 58)