Owner`s manual
11.0 ME-AGS-N Remote Status Messages
© 2012 Magnum Energy, Inc. 86
Table 11-2, AGS Remote Start Statuses
STATUS REMOTE DESCRIPTION
Start Amp ARC/RTR The generator has started based on the SETUP:
04C Gen Run Amps setting.
Start
Exercise
ARC/RTR The generator has started based on the SETUP:
04H Gen Exercise setting.
Start SOC ARC/RTR The generator has started based on the SETUP:
04D Gen Run SOC setting.
Start
Temp
RC The generator has started based on the AGS: 04
Start Temp setting.
ARC/RTR The generator has started based on the SETUP:
04E Gen Run Temp setting.
Start Test RC/ARC/
RTR
The AGS is in Test mode. Test mode may be
started from the TEST button located on the
AGS,
RC or, by selecting “Test” from the AGS: 01 AGS
Control menu (see Section 5.1 for further infor-
mation on the AGS’s TEST button).
Start Time ARC/RTR The generator has started based on the SETUP:
04B Gen Run Time setting.
Start
Topoff
ARC/RTR The generator has started based on the SETUP:
04G Quiet Time Topoff Time setting.
Start VDC RC The generator has started based on AGS: 05
Start Volts setting.
ARC/RTR The generator has started based on SETUP: 04A
Gen Run VDC setting.
11.2 AGS Remote Start Statuses
The following “Start” statuses identify the condition that autostarted the
generator. If you determine that the autostart condition occurred sooner
than expected (or didn’t want this autostart condition), refer to the Setup
section for your specifi c remote to change (or defeat) the autostart setting.