Installation Manual

Page 118
© 2014 Magnum Energy, Inc.
Using a PT Controller: Operation/Monitoring
SETUP
continued….
[Status/Fault]
06 PT Setup
P
continued….
R
R
R
LEGEND
Menu Selection
Menu Button
PT Status/Meter
Menu Item
Inverter/Charger Status
METER
Press button
Press SELECT
R
= rotate SELECT knob
07A PT Status
Press SELECT
[Status/Fault]
07 PT Meters
P
Set Bulk Start
Volts = 12.0
06E Bulk Start
Press SELECT
P
R
Set Bulk Start
Daily/SunUp=YES
NO
P
P
Set Bulk Start
SOC = 80%
R
R
OFF,9.0-16.0
OFF,50-99%
P
06F PT Aux Relay
10.0 to 14.0
06G PT Alarm
10.0 to 14.0
06H PowerSave PT
Display =15 Min
P
Relay Engage
Volts = 10.0
R
8.0-16.6
Relay Engage
Delay = 10 Sec
Relay Disengage
Volts = 14.0
Relay Disengage
Delay = 10 Sec
P
P
P
R
0-127 Sec,1-127 Min
R
R
8.0-16.6
0-127 Sec,1-127
Min
Set Alarm ON
Volts = 10.0
R
8.
0-16.6
Set Alarm ON
Delay = 10 Sec
Set Alarm OFF
Volts = 14.0
Set Alarm OFF
Delay = 10 Sec
P
P
P
R
0-127 Sec,1-127 Min
R
R
8.0-16.6
0-127 Sec,1-127 Min
Set Powersave PT
Display =15 Min
R
OFF,1-60 Min
P
Figure 10-8, PT Charge Controller SETUP Menu Map