Installation Manual

Appendix A – ME-ARC Compatibility Matrix
Page 125
A-1 Remote Feature to Inverter Compatibility
The ME-ARC has many settings and is designed to work with the advanced features in your Mag-
num inverter—and/or other Magnum devices (i.e., ME-AGS-N, ACLD-40, PT-100 or ME-BMK).
The remote communicates with your inverter to allow the set up and enabling of these advanced
features. However, when the ME-ARC is released with new software, some of the features and
functionality in the remote may not be available in an inverter or networked accessory that has
an earlier software level. In this case, the advanced setting is not recognized and will not func-
tion. Use the steps below to help you determine which ARC (Version 4.0) menus/features are
compatible with your inverter.
1. Go to: http://magnumenergy.com/inverter-compatibility/ to determine your inverter’s com-
patibility level (L1, L2, L3, or L4).
2. Use Table A-1 to determine which ME-ARC ‘features/settings’ you want to use and what in-
verter compatibility level is required (see the “Model/Level Required” column in Table A-1).
3. If your inverter compatibility level is the same or greater than the level required, your in-
verter can support the device setting/feature you want.
4. If your inverter does not have the required compatibility level for a feature/setting you want,
contact Magnum Energy for a software upgrade.
Info: The ME-ARC compatibility matrix below is also available online to download or
to print as a single page document. To download or to print, go to:
http://magnumenergy.com/inverter-compatibility/
Table A-1, ME-ARC (Version 4.0) Compatibility Matrix
Button
Features/Settings
Model/
Level
Required
Default
Main
Menu
Menu
Heading/Item
Selections/
Adjustments Range
CTRL
01 ACIn Control
Auto Connect Level 1
Auto
Connect
VDC Connect, Time Connect,
ACIn – Disabled
Level 3
[1]
SOC Connect Level 3 [1][6]
02 CHG Control
Multi-Stage, Start Float, Start
Bulk
Level 4
Multi-
Stage
03 Gen Control OFF, ON, AUTO Level 1 [7] OFF**
04 PT
Control
04A PT CHG Ctrl
Multi-Stage, Charger Off, Start
Float, Start Bulk, Start EQ
Level 4
Multi-
Stage
04B PT Aux Relay
Ctrl
DISENGAGE, VDC, FAULT,
ENGAGE
DISEN-
GAGE
04C PT Alarm Control OFF, VDC, FAULT, ON OFF
04D PT MPPT Sweep
5 Min, 15 Min, 1 Hour,
Fixed Sweep
15 Min
Sweep
METER
01 DC
Meters
01A DC Volts
Read Only display Level 1
Read
Only
01B DC Amps
02 AC
Meters
02A AC Output
Read Only
Level 4
Read
Only
02B Load Amps
Level 4 [3]02C Input Amps
02D Inv/Chg Amps