www.Magnum-Dimensions.com April 2020 PN 64-5029 Rev A
From the ME-MR Remote Control version 1.3 or higher,
program your Magnum Energy inverter/charger to
charge lithium batteries.
Press Menu/Home
button until the display
shows BAT AHRS
The current “saved
setting is indicated by
an arrow in the bottom
right-hand corner of
the display
Press On/Off/Change
button until 200 AH
is shown
STEP TWO: Set the Battery Type
setting to LFP.
LED Indicators
On/Off/Change Button
Menu/Home Button
Save/Hold Button
LCD Display
ME-MR Remote Control
BAT AHRS
400 AH
BAT AHRS
200 AH
Press Save/Hold
button to save the
200 AH setting
BAT AHRS
200 AH
STEP ONE: Set the Battery Amp Hours
to 200 AH = 1 hour.
Press Menu/Home
button until the display
shows BAT TYPE
The current “saved
setting is indicated by
an arrow in the bottom
right-hand corner of
the display
Press On/Off/Change
button until LFP
is shown
BAT TYPE
FLOODED
BAT TYPE
LFP
Press Save/Hold
button to save the
LFP setting
BAT TYPE
LFP
BAT AHRS
400 AH
BAT TYPE
FLOODED
Guide provided for reference only. Please read the
full Owner’s Manual for each remote control.
STEP THREE: Set the Low Battery Cutout
to battery manufacturer’s specifications.
Press Menu/Home
button until the display
shows LBCO
The current “saved
setting is indicated by
an arrow in the bottom
right-hand corner of
the display
Press On/Off/Change
button until correct
Low Battery VDC
setting is shown for
your battery specs, or
11.0VDC if not specified.
LBCO
10.0VDC
LBCO
11.0VDC
Press Save/Hold
button to save the
LBCO setting
LBCO
11.0VDC
LBCO
10.0VDC