Operator`s manual

36
AUXILIARY FUEL TANK OPTION
The auxiliary fuel tank option is desgined so the unit can run from an external
fuel tank. The unit is still programed to shut down when the internal tank’s fuel
level drops below five percent. In order for the unit to run off of an auxiliary tank,
the fuel level in the internal tank must remain over five percent. To operate the
unit using an auxiliary fuel tank, use the following procedure:
1. Shut down the unit and check that the level of fuel in the tank is above five
percent.
2. Attach the auxiliary fuel tank's fuel lines to the “AUXILIARY FUEL INLET”
and “AUXILIARY FUEL OUTLET” fittings on the unit.
3. Open the “AUXILIARY FUEL INLET” and “AUXILIARY FUEL OUTLET”
valves located inside of the right front door.
FUEL TRANSFER PUMP OPTION
The fuel transfer pump option allows the fuel tank to be refilled from an external bulk fuel source. When the fuel
transfer switch is on, anytime the fuel level drops below 15% the fuel transfer pump will begin pumping fuel from an
external bulk fuel source into the fuel tank on the unit. The fuel transfer pump will shut off when the fuel level of the
internal tank reaches 90%. The pump will also be monitored to ensure a certain percentage increase in fuel level
over a given period of time to prevent the pump from running dry. To operate the fuel transfer system, use the following
procedure:
1. Shut down the unit. Note: if the external bulk fuel supply is already connected, the
unit does not have to be shut down to turn the fuel transfer pump option on or off.
2. Attach the external bulk fuel supply to “FUEL TRANSFER INLET” fitting on the unit.
3. Turn on the Fuel Transfer Switch.
CHECKING GENERATOR DRIVE PLATE TORQUE
Follow the procedure below to check the torque of the generator drive plate bolts in
accordance with the maintenance chart on page 34.
1. Remove the generator fan guard.
2. Torque each of the drive plate bolts to the appropriate specification shown in the table below.
3. Reinstall the generator fan guard.
Unit FT/LB
MMG75 36
MMG100 36
FUEL TRANSFER
INLET