Page 34© 2016 Sensata Technologies
Installation
Figure 2-17, AC Wiring for MS2000-15B/-20B Models
Main Panel
(Utility Power/Generator Input)
MS2000-15B/
MS2000-20B Inverters
AC Terminal Block
(AC input and output wiring)
SINGLE IN / DUAL OUT wiring
Direct from inverter
(Inverter Loads)
120
VAC
120
VAC
ON
OFF
ON
OF F
ON
OF F
ON
OF F
ON
OF F
ON
OF F
ON
OF F
ON
OF F
ON
OF F
ON
OF F
ON
OF F
ON
OF F
ON
OF F
30
.Maximum 30-amp breaker
(single pole) required to
inverter AC input.
In mobile installations: neutral is typically not
connected to ground in the main panel.
AC HOT. 1 OUT
Has optional 15-amp or 20-
amp branch-rated circuit
breakers (on side of unit).
ORANGE
BLUE
AC HOT. 2 OUT
AC NEUT OUT
GREEN
AC GROUND (x2)
AC GROUND
WHITE
AC NEUT IN
AC HOT IN
BLACK
AC NEUT OUT
.WHITE w./ BLACK
.WHITE w./ BLACK