User Manual
Page 58
© 2016 Sensata Technologies
Appendix A – Specifi cations
Models
MS2000/12
MS2812 MS2024 MS4024
MS4048
MS2012 (-15/-20B) MS4048-20B
Inverter Specifi cations
Input battery voltage range 9.0 to 16.8 VDC 18.0 to 33.6 VDC 36.0 to 67.6 VDC
Absolute maximum DC input 25 VDC 35 VDC
AC output voltage accuracy 120 VAC ±5% (≤ continuous power)
Output frequency and accuracy 60 Hz ± 0.1 Hz
Total Harmonic Distortion (THD) < 5%
Continuous power output (at 25°C) 2000 VA 2800 VA 2000 VA 4000 VA 4000 VA
Continuous AC output current 17 A 23 A 17 A 33 A
1 msec surge current (amps AC) 50 70 75 120
100 msec surge current (amps AC) 33 40 37 82 72
5 sec surge power (real watts) 3300 3900 2850 5800 8500
30 sec surge power (real watts) 3100 3800 2750 5400 5750
5 min surge power (real watts) 2800 3200 2700 4900 5250
30 min surge power (real watts) 2200 3000 2200 4500 4750
Maximum continuous input current 267 ADC 373 ADC 133 ADC 267 ADC 133 ADC
Inverter effi ciency (peak) 90.6% 90% 86% 93.7% 94.0%
HBCO/HBCI (High Battery Cut Out/In) 16.8/16.5 VDC 33.6/33.0 VDC 67.6/66.7 VDC
LBCO/LBCI (Low Battery Cut Out/In) 9.0 (adj)/12.5 VDC 18.0 (adj)/25.0 VDC 36.0 (adj)/50.0 VDC
Series stacking for 120/240 VAC No Yes, using two MS4024s, or two MS4048s*
AC Relay transfer time (minimum) 16 msec
Power consumption – searching <8 watts
Power consumption – inverting (no load) 25 watts 30 watts 25 watts
Output waveform Pure Sine Wave
Charger Specifi cations
Continuous charger output at 25°C 100 ADC
125 ADC 60 ADC 105 ADC 60 ADC
Input current for continuous rated output 15 AAC
18 AAC 7.9 AAC 29 AAC 30 AAC
Charger effi ciency 85%
AC input range (frequency/voltage) 50 to 70 Hz/ 60 to 140 VAC (120 VAC nominal)
Power factor > 0.95
General Features and Capabilities
Transfer relay capability 30AAC max. each input (30AAC total on MS2000 models, 60AAC total on all other models)**
Five-stage charging capability Bulk, Absorb, Float, Equalize (requires remote), and Battery Saver™
Battery temperature compensation Standard with available temp sensor connected (battery temp 0 – 50°C)
Internal cooling 0 to 120 cfm variable speed drive using dual 92 mm brushless DC fan
Overcurrent protection with two overlapping circuits
Over-temperature protection on transformer, MOSFETS, and battery
Corrosion protection PCB’s conformal coated, powder coated chassis/top, and stainless steel fasteners
Safety listings
ETL listed to UL/cUL 458, UL 1741, CSA C22.2 No. 107.1-01, and meets KKK-A-1822E std.***
Warranty 3 years parts and labor
Branch-rated output circuit breakers Optional on MS2000 (15 or 20 amp breakers) or MS2012 (15 or 20 amp breakers)
Environmental Specifi cations
Temperature (Operating/Non-operating) -20°C to +60°C (-4°F to 140°F)/-40°C to +70°C (-40°F to 158°F)
Operating humidity 0 to 95% RH non-condensing
Physical Specifi cations
Unit dimensions (length x width x height)
13.75” x 12.65” x 8.0” (34.9 cm x 32.1 cm x 20.3 cm) [Height on MS2000 models is 7.0”/17.8 cm]
Shipping dimensions (L x W x H) 19” x 17” x 13” (48.3 cm x 43.2 cm x 33 cm)
Mounting Shelf or wall (vents not allowed to face downward unless ME-CB or MMP/MP is installed)
Unit weight 42 lb (19.1 kg) 55 lb (24.9 kg) 41 lb (18.6 kg) 55 lb (24.9 kg) 55 lb (24.9 kg)
Shipping weight 48 lb (21.8 kg) 62 lb (28.1 kg) 49 lb (22.2 kg) 62 lb (28.1 kg) 62 lb (28.1 kg)
Max operating altitude 15,000’ (4570 m)
* The MS4048-20B model is not series stackable.
** The pass-thru capability on each leg of the – 15B and – 20B models is limited by the output breaker size on each output.
*** MS2000 models
ETL listed to UL/cUL 458, CSA C22.2 No. 107.1-01, and meet KKK-A-1822E standard.
Specifi cations @ 25°C – Subject to change without notice.
Appendix A – Specifi cations and Optional Equipment
A-1 Inverter/Charger Specifi cations