5 Installation
Before installing a new EC2000, be sure to consult section 3 Planning to make sure all supporting
electrical, network, and physical infrastructure are in place.
5.1 Installation Checklist
Follow these steps to install the EC2000 (see this YouTube video for a demonstration):
1) Determine how the EC2000’s chassis will be secured, per the physical installation plan (see section
3.1 Physical Installation Planning).
2) If the physical installation plan includes using the security anchor on the rear of the device, thread a
cable or chain through the security anchor (see Figure 5-1), and lock the cable to a secure stationary
anchor point.
Figure 5-1 - Security Anchor
3) If the plan includes bolting the EC2000 chassis directly to the surface it is installed on:
a) Open the EC2000’s top access door (see section 6.5 Top Access Door Security for details).
b) Remove the two thumb screws on the left side of the backplane (see Figure 5-2) and remove the
service access door on the bottom left side of the device.
c) Locate the 3/8 inch diameter anchor hole in the front right of the lower chassis (see Figure 5-3).
d) Select an appropriately-sized lag bolt or similar anchoring device and make sure it fits the hole.
e) Use a pencil to lightly mark the mounting surface through the anchor hole.
f) Use a pencil to lightly outline the EC2000’s front feet on the mounting surface.
g) Move the EC2000 to expose the hole marked on the mounting surface.
h) Drill a through-hole sized for the mounting hardware at the mark, and make sure the mounting
hardware fits through the hole without slipping all the way through.
i) Move the EC2000 so its feet and anchor hole line up with the hole and marks.
j) Fasten the mounting hardware to the surface through the anchor hole, making sure it is secure.
MagTek recommends feeding a lag bolt up through the mounting surface into the EC2000 chassis
and attaching a nut inside the EC2000.
k) Replace the left service access door and thumb screws, and close the top access door.