Manual
<IntelliCAT>| <Migration to Windows 7> | <User Support Document>
Page 10
SQL Users Only
Action required
If a SQL database is being used in an old XP 2.XX and
you are migrating to a Win 7 32bit environment, a
Controller.UDL is not required but one may be in use.
32bit PC - Controller.UDL, if in use
No change is required to the current *.UDL's
including the Controller.UDL
64bit PC - Controller64 UDL, create new UDL Complete Step 12B as referenced above (create a
new Controller64.UDL only and change the
connection string to reflect Program Files (x86) in
the path structure and change the [ODBC]
WorkQConnect path to reflect Controller64.UDL
Note: Both the Controller.UDL and the Controller64.UDL will be used during the migration process from old
XP 2.XX 32bit to the new Win 7 64bit install.
Important Note: If migrating from a local XP 1.XX to a local 2.XX using a Win 7 32/64bit PC – and all paths
point to the local PC and all modification have been made to the desktop INTCAT.INI file, Click File, Save
and Close. Copy the Desktop INTCAT.INI file to C:\Windows and overwrite the existing file.
Go to Step 13 to Import Operators from a 1.XX install only and Skip Steps 14 thru 17
Step 13 – Importing Operators Local Install only
ICAT Utility is only required when migrating from 1.XX to 2.XX regardless of O.S.
If migrating from XP 1.XX IntelliCAT: Use ICAT Utility to import old operators. Instructions are in a
separate document named ICAT Utility Instructions.
Note - If migrating from XP 2.XX to Win 7, the old Databases will still be in use, copied in Step 11, so there
is no need to import operators. Do not continue with STEP 13 A or Step 13 B
Use the copy of the Old \IntelliCAT\1.X_MTAdmin.mdb, previously saved and renamed.
o If an Operator(s) folder is not present, follow Step 13 A only.
o If an Operator(s) folder exists, skip Step 13 A and go directly to Step 13 B.
13 A - Import Operators from Old 1.X_MtAdmin.mdb
into the new \IntelliCAT\MTAdmin.mdb database.
In either a 32 bit/64 bit PC, when using ICAT Utility, Utilize the copy of the 1.X_MtAdmin.MDB to
import Operators using the new C:\...\IntelliCAT\MtAdmin.MDB via the newly created IntelliCAT.UDL
or IntelliCAT64.UDL file (O.S. Dependent).
13 B - Import Operators from Local Old 1.X_OperatorMtAdmin
into the new …\Operators\MtAdmin.mdb database
If an Operator(s) folder is present in either 32bit/64bit PC, navigate to the appropriate folder: i.e.
C:\....\IntelliCAT\Operators\ O.S dependent.
Make a Copy of the NEWLY INSTALLED MtAdmin.MDB located in C:\.....\Magtek\IntelliCAT\ and
paste the copy into the local Operator(s) folder. Using ICAT Utility, Utilize the copy of
1.X_OperatorMtAdmin.MDB to import Operators into the New MtAdmin.MDB via the newly created
Operator.UDL or Operator64.UDL. (O.S dependent).