Step 10 A - SAVE Old XP 1.XX Local Install Files -
If Step 3 and 4 were performed, SAVE the files below.
This was an old XP 1.XX original install. Save files to a thumb drive or network folder.
First SAVE, then EDIT and RENAME where it states Mandatory. If the renaming is not completed as
required, the new installation will fail to work as the MtAdmin.MDB file
between versions 1.XX is not
compatible with the 2.XX MtAdmin.MDB file. This is a critical Step as highlighted below
...\IntelliCAT\BinList.TXT
32bit just Copy and Save. 64bit Copy, Save, then edit the file
to add (x86) to Program Files path. Click File, Save, Close
...\IntelliCAT\MtAdmin.MDB
Copy, Save, Mandatory - rename MtAdmin.MDB to
1.X_MtAdmin.MDB after saving
...\IntelliCAT\Operator(s)\MtAdmin.MDB
Copy, if present Save, Mandatory - rename MtAdmin.MDB to
1.X_OperatorMtAdmin.MDB after saving
...\InteliCAT\MTControllers.DAT
32bit just Copy and Save. 64bit, Copy, Save, then edit the file
to add (x86) to Program Files path. Click File, Save then close.
...\IntelliCAT\Card Layouts\
Copy, Save the entire folder
Step 10 B - SAVE Old XP 2.XX Local Install Files -
If Steps 3 and 4 were NOT performed, COPY, SAVE the files below. This was an old XP 2.XX original
install. Save files to a thumb drive or network folder.
Step 11 - Copying old files
Copy all of the old files and folders noted above in Step 10 to their respective locations:
32bit copy to C:\Program Files\MagTek\IntelliCAT\... --- Step 10 A
64bit copy to C:\Program Files (x86)\MagTek\IntelliCAT\... --- Step 10 B
Click YES to REPLACE ALL when copying.
Old Files from 2.XX Local Install
Mandatory Action Save Files below
...\IntelliCAT\BinList.TXT
32bit just Copy and Save. 64bit Copy, Save, then edit the file
to add (x86) to Program Files path. Click File, Save and close.
...\IntelliCAT\MTAdmin.MDB
Copy, Save
...\IntelliCAT\Operators\MTAdmin.MDB
Copy, Save the Operators folder if present
...\InteliCAT\MTControllers.DAT
32bit just Copy and Save. 64bit Copy, Save, then edit the file
to add (x86) to Program Files path. Click File, Save and close.
...\IntelliCAT\Card Layouts\
Copy, Save the entire folder
...\IntelliCAT\*.UDL's
Copy, Save all the UDL's only if the [ODBC] path structure
is referencing the local PC, i.e.
C:\Program Files\MagTek\IntelliCAT\IntelliCAT.UDL
If the [ODBC] section is referencing a
UNC or Mapped Drive Path structure
i.e. \\server1\MagTek\MagTekUDL\...
DO NOT copy the *.UDL's from the local folder.
And DO NOT TOUCH the networked UDL files.
Old Files From 1.XX Install
Mandatory action - Save Files below