Owner manual

127
APPENDIX F. LIST OF PROPERTIES
This list shows all of the properties that are supported among the MagneSafe reader families. The properties associated with a particular MagneSafe
model are indicated with a check mark. The default setting for each property is indicated.
Properties Default
Dynamag
Dynamo
LCD
BulleT
SPP
BulleT
KB
Flash iDynamo U-Finity Insert
UART
RS-232
HID KB
PID For USB Devices 0011
0001
0011 0011 0011 0011
n/a 0014
0013
n/a
0x00 Software ID
Shows part number
of installed firmware
0x01 USB Serial Num
No string with a
length of zero
0x02 Polling Interval 1 ms
0x03 Device Serial Num
No string with a
length of zero
0x04 MagneSafe Version
Number
"V05"
0x05 Track ID Enable 0x95
0x07 ISO Track Mask "04040Y"
0x08 AAMVA Track Mask "04040Y"
0x0A Max Packet Size 8
0x0A RS-232 Comm Parameters 0x02
0x0B Activity Timeout Period 120 (0x78) seconds
0x0D Bluetooth Disconnect
Message
No string with a
length of zero
0x0D Track Data Transmission
Delay
50 (500 milliseconds)
0x0E Stay Powered After Swipe
0x00 (Don’t Stay
Powered)
0x0F RF Address 0x12345678 (hex)
0x10 Interface Type 0x00 (HID)
0x10 Interface Type 0x01 (KB)
0x10 Interface Type 0x02
0x10 Interface Type 0x03
0x14 Track Data Send Flags 0x63