Owner's manual

MICRSafe with 3-Track MSR
20
RD00<CR> (to disable the use of the auxiliary RS-232 port)
or
RD01<CR> (to enable the use of the auxiliary RS-232 port for transmitting MSR data
only)
or
RD02<CR> (to enable the use of the auxiliary RS-232 port for transmitting check data
only)
or
RD03<CR> (to enable the use of the auxiliary RS-232 port for transmitting both MSR
and check data)
If no data is sent, the MICRSafe responds with the current value of RD.
CHKCNTCHECK COUNT COMMAND
This command returns the number of checks that have been processed by the device. To
execute, send the CHKCNT command followed by a carriage return as follows:
CHKCNT<CR>