Owner's manual
53
APPENDIX C. TROUBLESHOOTING GUIDE
REQUIREMENTS
• Personal Computer.
• USB Cable, P/N 22553301
• DC adapter, P/N 64300118 (64300121 for international customers).
• MICRbase setup program, P/N 22000021.
• Sample checks, P/N 96530005.
• A small bottle of compressed air.
• A cleaning card, P/N 96700006.
SET-UP
• Plug the USB Cable, P/N 22553301, into the MICRSafe and the host computer.
• Power on the MICR Reader.
• Run the MICRbase program on the PC.
• Start trouble-shooting procedure at Step 00.
00 CHECK LED
Check the status of the LED indicator:
◊ off, continue to step 01.
◊ green, continue to step 02.
◊ blinking red, continue to step 11.
◊ blinking red/green, continue to 12.
◊ red or orange, continue to step 18.