Owner's manual

MICRSafe with 3-Track MSR
54
01 CHECK THE POWER TO THE MICRSAFE
Possible causes for this problem are:
DC adapter connection to outlet - make sure the DC adapter is securely connected to outlet
on the wall or power strip.
DC adapter connection to MICRSafe - make sure the DC adapter is securely connected to the
power jack on the MICRSafe.
Power strip - if using a power strip, make sure the strip is connected to outlet on the wall and
the switch on the strip is turned on.
DC adapter is defective - replace the DC adapter.
Determine if any of the conditions described above are true:
If yes, rectify and continue to step 00.
If no, continue to step 18.
02 READ A CHECK
Read a check through the MICRSafe:
If the check is transported all the way around the check path, continue to step 03.
If the check gets "stuck" in the check path, continue to step 10.
If the motor does not turn on, continue to step 18.
03 DID PC RECEIVE DATA?
After the check is read, did the PC receive any data?
If yes, continue to step 04.
If no, continue to step 05.
04 ANALYZE DATA
Analyze the data received by the PC:
If the data is good, continue to step 16.
If the data contains one or more '?', continue to step 06.
If the data is missing characters, continue to step 07.
If the data is garbled, continue to step 08.
If the data is good but not what is expected, continue to step 09.