User`s manual

23
Magtrol Model DSP6001 Dynamometer Controller
Chapter 3 – Installation/Configuration
SETUP
3.2.4.2 Software Configuration
1. Turn on the DSP6001 and proceed to the dynamometer configuration menu. See Section
3.2.1 – Dynamometer Configuration Menu.
2. Select TSC1 until HD is reached.
3. Select TSC2 until AUX is reached.
4. Press SHIFT to get to the hysteresis setup menu. See Figure 3–9 Hysteresis Setup Menu.
5. Press TORQUE UNITS button until the desired input unit for TSC1 is reached.
6. Press SHIFT. The display should appear as follows:
POWER
BRAKE STATUS SET POINT SET POINT P I D
TORQUE SPEED STATUS
Figure 3–15 TSC2 Aux Setup Menu
7. Press TORQUE UNITS button and use UP and DOWN buttons and Decrease/Increase
dial to set desired scale factor for TSC2.
8. Press SHIFT 3 times to return to the main menu.
9. To display the TSC2 auxiliary information in the main menu STATUS area, press SHIFT,
AUX SETUP and the POWER UNITS button until the display says ON. See Figure 3–12
Aux Setup Menu - Display On.
10. Press SHIFT to complete the initial setup and return to the new main menu. The display
should appear as follows:
POWER
BRAKE STATUS SET POINT SET POINT P I D
TORQUE SPEED STATUS
Figure 3–16 TSC1 with AUX Output Menu