User`s manual
34
Magtrol Model DSP6001 Dynamometer ControllerChapter 3 – Installation/Configuration
SETUP
8. Press SHIFT 2 times to get to the TSC2 Powder Brake Setup Menu as shown below.
POWER
BRAKE STATUS SET POINT SET POINT P I D
TORQUE SPEED STATUS
Figure 3–29 TSC2 Powder Brake Setup Menu
9. Press TORQUE UNITS button and use UP and DOWN buttons and Decrease/Increase
dial to set desired scale factor for TSC2.
10. Press SHIFT 2 times. The menu will appear as shown in Figure 3–25 Tandem Configuration
Menu.
11. Press the COM SETUP button until the menu says “YES”.
12. Press SHIFT once to reach the Maximum Speed Excited Menu as shown below.
POWER
BRAKE STATUS SET POINT SET POINT P I D
TORQUE SPEED STATUS
Figure 3–30 Maximum Speed Excited Menu
13. Press the AUX SETUP button and use UP and DOWN buttons and Decrease/Increase
dial to set maximum speed excited of PB.
14. Press SHIFT 3 times to complete initial setup and return to the main menu.