User`s manual

35
Magtrol Model DSP6001 Dynamometer Controller
Chapter 3 – Installation/Configuration
SETUP
3.2.12 in-Line torqUe tranSDUCer CroSS Loop fUnCtion
3.2.12.1 Hardware Connection
DYNAMOMETER / TSC1
AUX / TSC2
SUPPLY 2
SUPPLY 1
RS-232C
GPIB/IEEE–488
BRAKE
ACCESSORY
TORQUE–SPEED
OUTPUT
CTRL OUT
BRAKE FUSE
CAUTION: DOUBLE POLE FUSING
75VA 50/60Hz
EARTH
GROUND
FUSE (5×20mm):
120V UL/CSA 800mA 250V SB
240V IEC 315mA 250V T
(5×20mm):
UL/CSA 1.25A 250V SB
IEC 1A 250V T
MAGTROL, INC. BUFFALO, NY
Torque Transducer
(TM)
No Connection
DES 31x
Hysteresis
Brake
Eddy-Current/
Powder Brake
OR
DSP6001
DYNAMOMETER
CONTROLLER
GPIB
RS-232
M-TEST
or
PC
Figure 3–31 In-Line Torque Transducer Cross Loop Function
Note: In the Torque Transducer Cross Loop Function, the TM2XX is
connected to TSC2 while controlling the outputs of TSC1. The
connection allows closed loop control of a brake via the Torque
Transducer.
3.2.12.2 Software Configuration
1. Turn on the DSP6001 and proceed to the dynamometer configuration menu. See Section
3.2.1 – Dynamometer Configuration Menu.
2. Select TSC1 until BRAKE is reached.
3. Select TSC2 until TM2XX is reached.
4. Press SHIFT to get to the Torque Transducer Setup Menu as shown in Figure 3-11.
5. Press TORQUE UNITS button and use UP and DOWN buttons and Decrease/Increase
dial to set desired scale factor for TSC2.
6. Press SHIFT 2 times to reach the Brake Type menu as seen below.
POWER
BRAKE STATUS SET POINT SET POINT P I D
TORQUE SPEED STATUS
Figure 3–32 Brake Type Menu
7. Press POWER UNITS button until desired Brake Type is reached.