User`s manual

43
Magtrol WB/PB Dynamometers
Chapter 2 – Installation / Mounting
2.1.2 WB/PB 43 SerieS
WB/PB 43 Series Dynamometers are fitted with a connecting screw between the stator assembly
and the load cell. After installing the dynamometer on a test bench, fasten the connecting screw to
get the load cell operational. Proceed as follows and refer to figure 2–2:
Caution: while tightening the sCrew , keep the wrenCh parallel to the
vertiCal ConneCting rod to avoid load Cell overload.
1. Insert the hexagon cap screw
supplied with the dynamometer into the rod end .
2. Fasten the screw
.
Note: The overload protection screws and nuts and are adjusted
at the factory (refer to Chapter 6 Calibration for possible
adjustments).
Figure 2–2 WB/PB 43 Load Cell Locking System