Manual

Page 11
IMPORTANT
Check transmission fluid level according to manufacturer’s
instructions before connecting the ATX-3
Transmission must be up to operating temperature
Adjust fluid level if required
Indicator
Slide
Hose
Dip Tube
Quick Coupler
Hose
Black
560-80414-00
560-80414-00
Dipstick
Slide Indicator
Dip Tube Hose
Notch
DIPSTICK MODE
CONNECTING TO THE TRANSMISSION SYSTEM
1. Remove transmission dipstick.
2. Hold notched end of Dip Tube Hose even with the end of the dipstick as shown above.
3. Position the slide Indicator so that is even with the cap end of the dipstick.
4. Insert notched end of Dip Tube Hose into transmission so that the Slide Indicator is even with
the top of the dipstick port as shown above.
5. Attach Quick Coupler to other end of Dip Tube Hose.
6. Insert Quick Coupler into fitting on end of the black hose on the left side of the ATX-3.