User Manual

9
E X A M I N E I D
S
A M P L E
H O S E / F I L T E R F O R O I L
S T A R T T O C O N T I N U E
S T O P T O E N D
O
N N E
T I D E N T I F I E R
S A M P L E H O S E T O L O W
S I D E
P R E S S Y E S W H E N D O N E
G
A
S
A N A L Y
S
I
S
I
S
I N
P R O C E S S . . P L E A S E
W A I T
R E M
O
V E I D E N T I F I E R
S A M P L E H O S E F R O M L O W
S I D E
P R E S S Y E S W H E N D O N E
I D R E
S
L T
S
:
R 1 3 4 : # # . # %
,
A I R : # # . # %
H C : # # . # % P R E S S N O T O
R E J E C T
,
Y E S T O A C C E P T
>
5
%
A
I R
S
G
G
E
S
T
S
E X C E S S O I L I N S
A
M P L E
H O S E / F I L T E R . R E M E D Y
B E F O R E U S E . C O N T I N U E ?
Inspect the identifier hose for traces of oil
contamination. If oil is present in the hose, remove the
contaminated hose section or replace the entire hose
assembly. See REFRIGERANT IDENTIFIER
MAINTENANCE section of manual. Press START key.
Connect refrigerant identifier hose found on the rear of
the RHS980 to the cylinder of new refrigerant. Unit
includes an adapter to convert the ½ inch Acme fitting
on the cylinder to low side coupler. Cylinder of new
refrigerant must be upright with valve at top of
tank. Press YES key.
Sample of new cylinder refrigerant is processed and
the hose and coupler must be removed. Press
START key.
This shows the results from the refrigerant sample
processed. Select NO key to reject these results or
YES key to accept the results. Pressing NO will return
to the initial screen.
If the results from the refrigerant identification show an
air percentage above 5%, this screen will appear.
Inspect the id filter, sample hose and coupler filter prior
to the next identification to ensure these devices are
free of oil contamination. See REFRIGERANT
IDENTIFIER MAINTENANCE section for more
information.
This is a reminder that the cylinder of new refrigerant
must be connected to the yellow hose on the rear of
the RHS980. Press START key.
Refrigerant will be transferred from the cylinder on the
rear platform into the internal charge cylinder of the
RHS980. Cylinder of new refrigerant must be
upside down with valve at bottom of tank.
The amount transferred will be displayed.
Note: Pressing the STOP key will start an internal
clearing process. This process must run to
completion to remove internal refrigerant.
C O N N E C T H O S E T O
S O U R C E T A N K
O P E N V A L V E
S T A RT?
F I L L C Y L I N P R O C E S S
A M T F I L L E D # # . # L B
S T O P T O E N D
F I L L C Y L I N P R O C E S S
T I M E L E F T # # . # #
S T O P T O E N D