User Manual

29
P
A
S S W O R D S
A
C C E P T E D
C O N T I N UE?
E N T E R N E W S E R V I C E
M
A
N
A
G E R S P
A
S S W O R D
# # # #
C O N T I N UE?
P
A
S S W O R D U P D
A
T E D
C O N T I N UE?
P R I N T P
A
R
A
M E T E R
S E T T I N G S ?
S E L E C T Y E S O R N O
Example of printout:
**********************
R T I T E C H N O L O G I E S
R H S9 8 0
D A T E : # # - # # - # # # #
T I M E : # # : # #
P R I N T O U T P A R A M E T E R S E T
I T E M D E F S E T
L A N G U A G E E N G X X X
B U Z Z E R N O X X X
R E F I D N O X X X
A C D B I N T X X X
P R I N T E R Y E S X X X
P R T F D N O N O
F I L L T A R G 8 . 0 0 X X X X X
I N T V A C 5 0 0 0 X X X X X
F I N V A C 2 0 0 0 X X X X X
V A C R U N T 1 0 X X
H O S E O V R 0 . 0 2 X . X X
M I N V O L T 9 0 X X X
E L E V S E A 4 0 0 X X X X X
O I L R I S E 5 0 X X X
* * * * * * * * * * * * * * * * * * * * * *
TOTAL CAPACITIES
T O T
A
L C
A
P
A
C I T I E S
C O N T I N UE?
C O M B O F I L T E R L I F E
R E M
A
I N I N G # # # L B S
C O N T I N UE?
This screen will be shown after the Default Password
has been accepted. Press START key to continue.
Enter the Service Managers new 4 digit password and
press YES to continue. Important once the Service
Managers default password has been changed, the
password must be remembered to make any further
changes.
This screen will be shown after the new Service
Managers password has been accepted. Press
START key to continue.
The RHS980 has the capability to print all of the user
selectable parameters to the printer or to a file. Press
YES key to access this feature.
If printing to a flash drive is enabled in the
SELECTABLE OPTIONS section, a file will be created
containing the parameter listing. File naming
convention is as follows: paramtr.txt. New data printed
will be appended to the end of the file. Use any text
editor software to view file contents.
The RHS980 records data which can be used for shop
management of the equipment and refrigerant usage.
Press START key.
The RHS980 combo filter must be replaced after every
150 LB (68 KG) of refrigerant has been recovered from
A/C systems. An alert will display when the filter life is
at 100 LB (45.35 KG). The RHS980 will shut down
when the filter life is at 150 LB (68 KG). A new filter
must be installed and a serial number entered to re-
start the RHS980. Press START key to go to next
screen.