User Manual

8
FIRST TIME USE
The first time a new RHS980 is powered up it will automatically perform a routine where the language is selected. The
language can be changed later if desired in the Setup Mode.
The RHS980 will arrive without any refrigerant. It will be necessary to put new refrigerant into the internal charge
cylinder before any other sequences can be run. The amount of refrigerant which to be transferred is factory set at 18
LB (8.16 KG). This amount can be adjusted if desired. Refer to SETUP section under DEFAULT VALUES to change
the factory setting. Connect the short yellow hose on the rear of the RHS980 to a new 30 lb. cylinder of refrigerant.
Open the cylinder valve, turn the cylinder up-side-down and place it on the platform. Secure with web belt.
Plug the power cord into an appropriate power source. Avoid using an extension cord. If necessary, use a good
condition, three wire grounded, #14 AWG or larger extension cord of the shortest possible length.
R H S 9 8 0
R T I - M A H L E C l e v i t e
X X X XXX
S E L E C T L A N G U A G E
E N G L I S H E S P A Ñ O L
F R A N Ç A I S D E U T C H
,
W E I G H T = # # . # L B
A U T O M A T I C
S T A RT?
W E I G H T = # # . # L B
R E C Y C L E
S T A RT?
W E I G H T = # # . # L B
V A C U U M
S T A RT?
W E I G H T = # # . # L B
C H A R G E
S T A RT?
W E I G H T = # # . # L B
F I L L C Y L I N D E R
S T A RT?
S
T A R T I N
G
R E F R I
G
E R A N T
I D E N T I F I E R
D O N O T C O N N E C T H O S E S
P L E A S E W A I T . . .
Press the Power Switch to turn on the RHS980.
The screen shown to the left will be displayed and a
buzzer will sound.
Press or key to scroll the displayed arrow to the
desired language. Press START key.
(Refer to Section CHANGING LANGUAGES for
additional information on loading new languages)
Note: Pressing the #4 key from the main menu will
access the language selection option.
The screen shown to the left will be displayed. Press
the key to scroll to the next screen.
Press key.
Press key.
Press key.
Press START key. If the internal cylinder capacity
is equal to or greater than the target amount
shown in DEFAULT VALUES, the FILL CYLINDER
process will not be available from the main menu.
If the RHS980 has a refrigerant identifier installed, the
screen to the left and next 6 subsequent screens will
appear. The refrigerant identifier is an optional item
and can be installed in the field. Contact RTI for more
information.