Operation Manual

1
When operating heating function
1 Disassemble the subassembly of outlet and the subassembly of exhaust pipe as
arrow direction Fig.01 and then exchange the two subassemblies to install. The
finished illustration is as Fig.03.
TROUBLE SHOOTING
Problem Cause Trouble shooting
E1 Electrical short on both temperature
sensor and PCB
Contact an electrician for repair
E2 Electrical short of temperature sensor
copper tube and PCB wiring
Contact an electrician for repair
E3 Leaking refrigerant from copper tube Contact an electrician for repair
E4 Indicates water tank full or possibly the
incorrect wiring of plug
User needs to pull out the rubber
stopper which is located at the
bottom of the unit, to drain the
water away. Check that the plug
has been wired correctly.
2
SPECIFICATION
Model No. SM35G SM40G
Power Source 220~240VV/50Hz 220~240VV/50Hz
Rated Power
(EN60335)
Cooling
Heating
1480W
1300W
1700W
1500W
Cooling Capacity 3500W 4000W
Heating Capacity 3500W 4000W
Moisture Removed 60 L/DAY 70 L/DAY
Refrigerant R410A R410A
Dimensions (mm) 300Wx505Dx778H 300Wx505Dx778H
Model No. SM26G SM26W
Power Source 220-240V~ 50Hz
Rated Power
(EN60335)
Cooling
Heating
950W
1100W
950W
1100W
Cooling Capacity 2600W 2600W
Heating Capacity 2600W 2600W
Moisture Removed 50 L/DAY
Refrigerant R410A