™ 12345678901234567890123456789012123456 12345678901234567890123456789012123456 12345678901234567890123456789012123456 12345678901234567890123456789012123456 12345678901234567890123456789012123456 12345678901234567890123456789012123456 12345678901234567890123456789012123456 12345678901234567890123456789012123456 12345678901234567890123456789012123456 12345678901234567890123456789012123456 12345678901234567890123456789012123456 12345678901234567890123456789012123456 12345678901234567890123456789012123456 123
SR/SC Series "A" Woodburning Fireplace Safety Information PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING FIREPLACE. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. Description The SR/SC Series "A" fireplaces are solid fuel, woodburning premium fireplaces.
SR/SC Series "A" Woodburning Fireplace SR36A Series Woodburning Fireplace 22" (559mm) Rough Opening Depth 48¹⁄₂" (1232mm) ¹⁄₂" (13mm) 22¹⁄₂" (572mm) 11" Dia. (279mm) 8¹⁄₄" (210mm) 8" Dia.
SR/SC Series "A" Woodburning Fireplace SR42A Series Woodburning Fireplace 26¹⁄₄" (667mm) Rough Opening Depth 50" (1270mm) ¹⁄₂" (13mm) 11" Dia. (279mm) 8¹⁄₄" 22¹⁄₂" (210mm) (572mm) 22" (559mm) 8" Dia.
SR/SC Series "A" Woodburning Fireplace Chase Installation Insulation methods shown are optional for cold climate, not a requirement for unit operation. Termination Cap Storm Collar Pan Flashing Batt Insulation (cut out around fiestop) Draftstop Firestop Ceiling Level Standoff Surround Damper Control Nailing Flange Gas Line Access (both sides) Gas Line Knockout (both sides) Screen Electrical Access Grate Firebox Outside Air Cover Plate Metal Safety Strips (1, 2 or 3 pieces) FP554 Fig.
SR/SC Series "A" Woodburning Fireplace Chimney Requirements - Offset Installations OFFSET CHIMNEY FLUE EXIT RISE CHIMNEY SECTION IWF282 B A D E 6 FT. G 30˚ RETURN ELBOW 30˚ OFFSET ELBOW RISE C H OFFSET 30˚ RETURN ELBOW 30˚ OFFSET ELBOW B 30˚ Elbow Offsets G SKCS8 SUPPORT H HEARTH FLOOR Example 1 Example 2 Example 3 Notes: G + H cannot exceed 20 feet.
SR/SC Series "A" Woodburning Fireplace Planning Information Preplanning an installation is very important to ensure safety and to save time and money. An installer must predetermine where a fireplace will be set and how the chimney system will be run. Mounting The Fireplace 1. A flat combustible surface. 2. A raised wooden platform. 3. A concrete block or other solid object placed beneath each of the four (4) corners of the fireplace.
SR/SC Series "A" Woodburning Fireplace Installation Chimney Supports The chimney system is supported by the fireplace for vertical chimney heights less than 30' (9m) above the hearth. Chimney supports are required if the vertical height exceeds 30' (9m) with SK8 chimneys or 20' (6m) with 3-wall chimneys. Locate chimney supports at ceiling holes or other structural framing at 30' (9m) (SK8) or 20' (6m) (3-wall) heights. Spacing between chimney supports must not exceed 30' (9m) (SK8) or 20' (6m) (3-wall).
SR/SC Series "A" Woodburning Fireplace Framing Option For Circulating Models Only — Framing can be constructed before or after the fireplace is set in place, however, most installers build the frame before setting the fireplace. Frame fireplace with 2 x 4 lumber or heavier materials. Refer to framing dimensions in Figures 1, 2, 3 or 4 for basic fireplace specifications. NOTE: Framing should be positioned to accommodate wall covering and fireplace facing material.
SR/SC Series "A" Woodburning Fireplace Straight-Up Chimney Installation To mark the centerline of the flue, put the fireplace in final position and measure out from the wall: 9¹⁄₄" (235mm). Mark a spot on the ceiling directly above the fireplace. Draw a line parallel to the back wall through this mark. (Fig. 11) Using a plumb bob positioned directly over center point of fireplace flue collar, mark the ceiling to establish the chimney center point. (Fig.
SR/SC Series "A" Woodburning Fireplace The following table gives firestop spacer model numbers: Angle of Chimney at Ceiling Vertical 30° SKFS2A SKFS6A 14¹⁄₂" x 14¹⁄₂" 14¹⁄₂" x 25¹⁄₂" (368mm x 368mm) (368mm x 648mm) 8" Flue FS2A FS6A "S" Series 3-Wall 17¹⁄₂" x 17¹⁄₂" 17⁷⁄₈" x 29⁵⁄₈" (445mm x 445mm) (454mm x 753mm) Size of Chimney 8" Flue "SK" Series NOTE: Safety strips are not required over noncombustible floors where all supports at the base of the fireplace are noncombustible.
SR/SC Series "A" Woodburning Fireplace Continue installing the pipe as required until pipe is installed up through the ceiling. At this point, you must install a firestop spacer. Pipe Section Pipe Rim UP Installing the Firestop Spacer in the Ceiling Hole Hem Lance Pipe Rim A firestop spacer is used to keep pipe spaced properly and required for safety. Nail the firestop spacer (at each corner) to the framing members of the ceiling hole. NOTE: A firestop spacer is not required at the roof.
SR/SC Series "A" Woodburning Fireplace Install the attic insulation shield with the flanges on its base extending down into the framing hole. Nail each corner of attic insulation shield to the framing members of the ceiling hole using 8d nails. Attic shields are not required at the roof.
SR/SC Series "A" Woodburning Fireplace Installing Top Housing or Termination Air Space Clearances Combustible framing material MUST NOT penetrate AIR SPACE (shaded areas). Follow the installation instructions provided with the chimney termination you have selected. Installing Chimney In a Chase Refer to Page 5, Figure 5 for an illustration of a typical chase installation. CAUTION: Treatment of firestop spacers and construction of chase may vary with type of building.
SR/SC Series "A" Woodburning Fireplace Mantel Clearance - Radiant Model - No Noncombustible Facing Material Combustible Mantel and Trim 12" (305mm) Max. 1¹⁄₂" (38mm) Mantel Clearance - Radiant Model - with Noncombustible Facing Material Combustible Mantel and Trim 12" Standoff (305mm) Noncombustible Min. Material Radiant Surround Face * 6" (159mm) Min. 12" (305mm) Max. Finished Wall 1¹⁄₂" (38mm) Header 12" (305mm) Min. Combustible Mantel and Trim 12" (305mm) Max.
SR/SC Series "A" Woodburning Fireplace Side Wall Protection Hearth Installation Adjacent combustible side walls that are within the minimum dimensions shown in Figure 23 of fireplace opening must be protected with CFM Corporation Wall Shield Model SP40 or a specifically built wall shield described below. A hearth extension is required to protect a combustible floor in front of the fireplace. Refer to Figure 23 for minimum dimensions and mounting detail.
SR/SC Series "A" Woodburning Fireplace COMMON MATERIALS AND FACTORS MATERIAL K* R Wall Covering MINIMUM THICKNESS Noncombustible Decorative Facing EH2416 (CFM Corporation) 0.458 1.09 Common Brick 5.0 0.10 Side View 0.50 in.** 2 x 4 Header (Do not notch at standoffs) Seal all cracks between fireplace surround and wall materials with noncombustible material 5.46 in.** R Value is for ¹⁄₂ inch.
SR/SC Series "A" Woodburning Fireplace Installing Line for Gas Logs Fireplace Top View Hole in Outer Casing CFM Specialty Home Products fireplaces are designed to accept a 1/2" (13mm) gas line for installation of an approved gas appliance. (CFM Specialty Home Products manufactures a wide variety of gas logs for use in CFM Specialty Home Products fireplaces.) Gas Line Tube Be sure to have the appliance installed in accordance with building codes. 1" Min.
SR/SC Series "A" Woodburning Fireplace 1 9 2 11 b 4 6 c d 3 a e 5 8 12 14 13 7 10 948 CFM Specialty Home Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. SR36A/42A, SC36A/42A SERIES For units FB40RO, GB40RO, FB40CO, GB40CO 1. 2. 3. 4. 5. 6a. 6b. 6c. 6d. 6e. 7. 8. 9. 10. 11. 12. 13. 14.
SR/SC Series "A" Woodburning Fireplace Accessories The following accessories for this appliance are available from your local Majestic Fireplaces distributor. Should you need additional information beyond what your distributor can furnish, contact: CFM Specialty Home Products, 410 Admiral Blvd., Mississauga, Ontario, Canada L5T 2N6, Attn: Technical Services.
SR/SC Series "A" Woodburning Fireplace Chimney Components U.S. Component Description Model Number Round Top Termination Top used to terminate chimney at roof. (Flashing not included.) RLTSK8 Round Top Termination Extended Top used to terminate chimney at chase. (Flashing not included.) RLTSK8L Flashing Metal finishing required around Contemporary Termination to prevent rain leakage.
SR/SC Series "A" Woodburning Fireplace (Chimney Components con't.) Canada Component 22 Description Model Number Chimney Collar Enclosure Installs on the "over the chimney collar" of the fireplace; provides outside air to assist in cooling the chimney system. CCE-SK Attic Insulation Shield Used to prevent insulation from coming in contact with the chimney system. AIS-SK SK8 Chimney Sections Used to build chimney systems exposed above roof. 45˚ Chimney Elbows Provides 45˚ offset and return.
SR/SC Series "A" Woodburning Fireplace ™ LIMITED WARRANTY & 30 YEAR PROTECTION PLAN For MAJESTIC FIREPLACES® PRE-ENGINEERED Fireplace Systems CFM Specialty Home Products warrants its MAJESTIC FIREPLACES® Pre-Engineered Fireplace (“Fireplace”) and the CFM Specialty Home Products supplied firegrate, glass doors, outside air system, fan motor, and liners to be free from defects in material or workmanship, as follows: A.
CFM Specialty Home Products 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777 www.majesticproducts.com • www.vermontcastings.