BR/BC Series Woodburning Fireplace Homeowner's Installation and Operating Manual For Models: BR36 BR42 BC36 BC42 WF553 BR/BC36 For use in U.S./Canada 11/10/97 Underwriter's Laboratories Report No. MH7603 DO NOT DISCARD THIS MANUAL: Retain for future use. 7412944 5/12 Rev.
BR/BC Series Woodburning Fireplaces Safety Information Please read this manual before installing and using FIREPLACE. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. Description The BR/BC Series fireplaces are solid fuel, woodburning fireplaces. The BR36/42 (Builder Radiant) is a clean-face fireplace and the BC36/42 (Builder Circulating) unit has fixed grilles.
BR/BC Series Woodburning Fireplaces BR36 Series Woodburning Fireplace 45 6M" (1162mm) 56O" (13mm) 11" Dia. (279mm) ) 6 " 56O" (187mm) * (521mm) 20" (508mm) 2m m 6M "( 6" 16 ( 1 45 6m m m m ) ) "( 82 6 8" Dia.
BR/BC Series Woodburning Fireplaces BR42 Series Woodburning Fireplace 11" Dia. (279mm) ) 6 " * 56O" (187mm) (521mm) 20" (508mm) 17 6 " 65 (1 m 6m m m ) 89 5m m ) 36 6 " (930mm) 42" (1067mm) 6 " (372mm) 6M" Gas Line (502mm) Access " (533mm) 6M" (197mm) 3" (76mm) Electrical Access 56M" (337mm) 8" Dia.
BR/BC Series Woodburning Fireplaces BR/BC36 BR/BC42 B C Front Width A 33Z\v" (845 mm) 39Z\v" (997 mm) Back Width B 19B\," (499 mm) 25B\," (651 mm) Depth C 15Z\v" (387 mm) 15Z\v" (387 mm) A FP1531 FP1531 Fig. 4a Hearth dimensions. hearth dimensions 9/04 djt Chase Installation Insulation methods shown are optional for cold climate, not a requirement for unit operation.
BR/BC Series Woodburning Fireplaces Chimney Requirements - Offset Installations OFFSET CHIMNEY FLUE EXIT RISE CHIMNEY SECTION FP282 B A D E 6 FT. C G 30˚ OFFSET ELBOW RISE H OFFSET 30˚ RETURN ELBOW 30˚ OFFSET ELBOW B 30° Elbow Offsets FP282 30˚ RETURN ELBOW G SKCS8 SUPPORT H HEARTH FLOOR Example 1 Example 2 Example 3 Notes: G + H cannot exceed 20 feet.
BR/BC Series Woodburning Fireplaces Planning Information Preplanning an installation is very important to ensure safety and to save time and money. An installer must predetermine where a fireplace will be set and how the chimney system will be run. Mounting the Fireplace A fireplace may only be mounted on the following surfaces: 1. A flat combustible surface. 2. A raised wooden platform. 3. A concrete block or other solid object placed beneath each of the four (4) corners of the fireplace.
BR/BC Series Woodburning Fireplaces Chimney Supports The chimney system is supported by the fireplace for vertical chimney heights less than 30' (9 m) above the hearth. Chimney supports are required if the vertical height exceeds 30' (9 m) with SK8 chimneys or 20' (6 m) with 3-wall chimneys. Locate chimney supports at ceiling holes or other structural framing at 30' (9 m) (SK8) or 20' (6 m) (3-wall) heights. Spacing between chimney supports must not exceed 30' (9 m) (SK8) or 20' (6 m) (3-wall).
BR/BC Series Woodburning Fireplaces Framing Framing can be constructed before or after the fireplace is set in place, however, most installers build the frame before setting the fireplace. Frame fireplace with 2 x 4 lumber or heavier materials. Refer to framing dimensions in Figures 1, 2, 3 or 4 for basic fireplace specifications. NOTE: When using 2 x 6 framing construction, the allowable air space between the front of the SK8 outer pipe and 2 x 6 framing is reduced to 1" (25mm) as tested and approved by U.
BR/BC Series Woodburning Fireplaces Straight-Up Chimney Installation To mark the centerline of the flue, put the fireplace in final position and measure out from the wall: 8¹⁄₄" (210 mm) Mark a spot on the ceiling directly above the fireplace. Draw a line parallel to the back wall through this mark. (Fig. 11) Using a plumb bob positioned directly over center point of fireplace flue collar, mark the ceiling to establish the chimney center point. (Fig.
BR/BC Series Woodburning Fireplaces The following table gives firestop spacer model numbers: Angle of Chimney at Ceiling Size of Chimney Vertical 30° 8" Flue SKFS2A SKFS6A "SK" Series 14¹⁄₂" x 14¹⁄₂" 14¹⁄₂" x 25¹⁄₂" (368 mm x 368 mm) (368 mm x 648 mm) 8" Flue FS2A FS6A "S" Series 3-Wall 17¹⁄₂" x 17¹⁄₂" 17⁷⁄₈" x 29⁵⁄₈" (445 mm x 445 mm) (454 mm x 753 mm) Fig. 13 Ceiling chimney hole sizes necessary for installing firestop spacer.
BR/BC Series Woodburning Fireplaces Installing the Chimney System Pipe Section Start by attaching the first chimney section to the collar on top of the fireplace. Pipe Rim UP Install the pipe as pictured in Figure 16. When you get a good lock, you will hear the pipe clearly snap together. Once sections are snap-locked in place, it is extremely difficult to get them apart. Make sure the pipe is firmly snapped and locked together as each pipe section is mounted.
BR/BC Series Woodburning Fireplaces Firestop spacers are not available for nor are they required on vertical walls. DO NOT put any sealant around the area where the outer pipe slides through the firestop spacer. If you seal this area, it may cause a fire hazard. Canadian Requirements for Insulation Shield NOTE: In the U.S., it is a good idea, although not always required, to install an attic insulation shield where blown-in insulation is planned to be used in the attic.
BR/BC Series Woodburning Fireplaces Install Remainder of Chimney Sections Since you have already preplanned the height of your termination according to the Ten Foot Rule, continue to install pipe to the predetermined height. Air Space Clearances Combustible framing material MUST NOT penetrate AIR SPACE (shaded areas). Check the chimney top installation instructions for details on how high above the roof top the chimney sections (all pipes) should extend.
BR/BC Series Woodburning Fireplaces Mantel Clearance - Radiant Model - No Noncombustible Facing Material Combustible Mantel and Trim 12" (305mm) Max. Finished Wall 156O" (38mm) Combustible Mantel and Trim Standoff Noncombustible Material * 12" (305mm) Max. Finished Wall 156O" (38mm) Header 12" (305mm) Min. Mantel Clearance - Radiant Model - with Noncombustible Facing Material 12" (305mm) Min.
BR/BC Series Woodburning Fireplaces Side Wall Protection Hearth Installation Adjacent combustible side walls that are within minimum dimensions shown in Figure 23 of the fireplace opening must be protected with a specifically built wall shield as described in Figure 20. A hearth extension is required to protect a combustible floor in front of the fireplace. Refer to Figure 23 for minimum dimensions and mounting detail.
BR/BC Series Woodburning Fireplaces WARNING: HEARTH EXTENSION MUST BE INSTALLED IN ACCORDANCE WITH FIGURE 23 AND MUST NOT COVER THE BOTTOM FRONT OPENING OF THE CIRCULATING MODEL. Example of Determining Hearth Extension Equivalents Alternate noncombustible materials may be used providing the (total) thermal resistance (Rt value) of the alternate material employed is greater than or equal to R = 1.09 Thermal resistance (R) or thermal conductivity (K), may be obtained from manufacturer of the material.
BR/BC Series Woodburning Fireplaces Installing Line For Gas Log MHSC fireplaces are designed to accept a 1/2 inch gas line for installation of an approved gas appliance. (MHSC manufactures a wide variety of gas logs for use in MHSC fireplaces.) Be sure to have the appliance installed in accordance with building codes. Gas connection may enter from either left or right side of the fireplace. Fireplace Top View Hole in Outer Casing Gas Line Tube 1" Min.
BR/BC Series Woodburning Fireplaces 1 9 2 b 4 c 5 d 3 a 7 11 12 6 8 10 MHSC reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, with out notice. BR/BC SERIES 1. 2. 3. 4. 5a. 5b. 5c. 5d. 6. 7. 8. 9. 10. 11. 12. Item/Model Number Damper Blade Weld Assembly Damper Bracket Screen Rod (two per fireplace) Screen Mesh (two per fireplace) Firebrick - Hearth* Firebrick - Rear* Firebrick - Rt. Side* Firebrick - Lt.
BR/BC Series Woodburning Fireplaces Accessories The following accessories for this appliance are available from your local MHSC Fireplaces distributor. Should you need additional information beyond what your distributor can furnish, contact: MHSC, 149 Cleveland Drive, Paris, KY 40361, Attn: Technical Services. CAUTION: This fireplace and chimney assembly is a highly engineered system, and, as such, must be operated only with MHSC approved components.
BR/BC Series Woodburning Fireplaces Chimney Components U.S. Component Round Top Termination Description Top used to terminate chimney at roof. (Flashing not included.) Round Top Termination Top used to terminate chimney at chase. Extended (Flashing not included.) Flashing Metal finishing required around Contemporary Termination to prevent rain leakage. Square Termination Top housing of simulated brick pattern Housing available in red, tan or white. Appropriate adapter required.
BR/BC Series Woodburning Fireplaces (Chimney Components con't.) Canada Component Chimney Collar Enclosure Attic Insulation Shield SK8 Chimney Sections 45° Chimney Elbows 22 Description Installs on the "over the chimney collar" of the fireplace; provides outside air to assist in cooling the chimney system. Used to prevent insulation from coming in contact with the chimney system. Used to build chimney systems exposed above roof. Provides 45° offset and return.
BR/BC Series Woodburning Fireplaces LIMITED WARRANTY Factory-Build Fireplace and Components (Except Blowers) What is Covered and For How Long Five-Year Coverage: For five years from the date this fireplace and components are first purchased for use, MHSC will, at its option, repair or replace any defective part of this fireplace or components, or refund to you a sum not to exceed the factory retail price in effect at the time of purchase.
MHSC 149 Cleveland Drive • Paris, Kentucky 40361 www.mhsc.