INSTALLER/CONSUMER SAFETY INFORMATION ™ PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE WARNING! IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. Builder Rear Vent Direct Vent Models: 33LDVR, 36LDVR, 39LDVR, 43LDVR FOR YOUR SAFETY Installation and service must be performed by a qualified installer, service agency or the gas supplier.
LDVR Series Direct Vent Gas Fireplace Table of Contents PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a CFM Specialty Home Products fireplace. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions fully may result in a possible fire hazard and will void the warranty. Installation & Operating Instructions Important Curing/Burning Instructions ................
LDVR Series Direct Vent Gas Fireplace Installation & Operating Instructions This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CSA-B149.1 Installation codes for Gas Burning Appliances and Equipment. For USA Installations follow local codes and/or the current National Fuel Gas Code. ANSI Z223.1/NFPA 54.
LDVR Series Direct Vent Gas Fireplace Fireplace Dimensions Rough Opening Depth S E R F U S V - Rough Opening Width Rough Opening Height T Low Voltage Access B Q Gas Line Access Centerline of 7" Collar C D M O P M A Gas Line Access Electrical Access Low Voltage Electrical Access J K L � � I H N G Fig. 2 Fireplace specifications and framing dimensions. Ref.
LDVR Series Direct Vent Gas Fireplace Clearance to Combustibles Top of Unit to Ceiling ............................. 36” (914mm) Appliance Top ....................................................... 0” (0 mm) Bottom .................................................. 0” (0 mm) Side ...................................................... 0” (0 mm) Back ..................................................... 0” (0 mm) Venting Concentric sections of DV Vent Top, bottom & sides ...........................
LDVR Series Direct Vent Gas Fireplace Framing and Finishing Check fireplace to make sure it is levelled and properly positioned. To mount the appliance: 1. Choose the location. 2. This unit comes with four (4) flanges pre-mounted on both sides of the fireplace to allow two different drywall thicknesses to be used. Flange “A” is for 1/2” drywall while flange “B” is for 5/8” drywall. 3. Bend the desired flanges out 90° on both sides of the fireplace.
LDVR Series Direct Vent Gas Fireplace Gas Line Installation When purging the gas lines, the front window frame assembly must be removed. The gas pipeline can be brought in through the rear of the appliance as well as the bottom. Knockouts are provided on the bottom behind the valve to allow for the gas pipe installation and testing of any gas connection.
LDVR Series Direct Vent Gas Fireplace EB-1 Electrical Box The fireplace, when installed, must be electrically connected and grounded in accordance with local codes or, in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code. For USA installations follow local codes and the national electrical code ANSI/ NFPA No. 70. It is strongly suggested that the wiring of the EB-1 Electrical Junction Box be carried out by a licensed electrician.
LDVR Series Direct Vent Gas Fireplace L1 BLACK L2 WHITE POWER CORD GREEN PURPLE PILOT SENSING CLEAR PILOT IGNITER YELLOW P O M O VALVE CIRCUIT BOARD BLUE ORANGE RED WHITE ON/OFF SWITCH OR WALL THERMOSTAT FP1571 Fig. 9 SIT822 Valve with Synetek electronic control wiring diagram. General Venting Your fireplace is approved to be vented either through FP1571 the side wall, or vertically through the roof.
LDVR Series Direct Vent Gas Fireplace General Venting Information - Termination Location INSIDE CORNER DETAIL V D H A V N N E L V B V F C B ����� ������ ��� ��� V V VENT TERMINATION B V �������� �� B CFM145a G B V J C = Clearance to permanently closed window D = Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2ʼ (610mm) from the center line of the terminal E = Clearance to unventilated soffit F = Clearance to outside corner G = Cle
LDVR Series Direct Vent Gas Fireplace Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. Inside Corner Recessed Location Outside Corner A= Combustible 6"(152mm) Noncombustible 2"(50mm) A V B= Combustible 6"(152mm) Noncombustible 2"(50mm) V C D E C V B Balcony with perpendicular side wall Balcony with no side wall G V V G= Combustible & Noncombustible 12"(305mm) C = Maximum depth of 48" (1219mm) for recessed location.
LDVR Series Direct Vent Gas Fireplace Twist Lock Pipes 30 To join the twist lock pipes together, simply align the beads of the male end with the grooves of the female end, then while bringing the pipe together, twist the pipe until the flange on the female end contacts the external flange on the male end. It is recommended that you secure the joints with three (3) sheet metal screws, however this is not mandatory with twist lock pipe.
LDVR Series Direct Vent Gas Fireplace Vent Opening for Combustible Wall 9³⁄₈” (240mm) 20" (508mm) Framing Detail 10³⁄₈” (264mm) Top View Straight Venting Fireplace Hearth DVR584-600 20" 20" Rear vent no elbows (508mm) (508mm) Max. Max. 2/99 djt Opening for Noncombustible Wall 7¹⁄₂” (190mm) 45° 45° Max. Length 12” (305mm) Adjustable Zero Clearance Sleeve Top View REAR VENT-TOP VIEW Rear Vent Corner Installation #8 Screws (2) Fig. 14 Rear vent applications, one 45° elbow.
LDVR Series Direct Vent Gas Fireplace Zero Clearance Sleeve Termination Flex Section Firestop Appliance Collars CFM133 Fig. 17 Firestop and zero clearance sleeve in place. CFM133 DVR Series Typical corner install Finished Wall 2/26/01 sta Vent Termination FP1473 Fig. 19 Grasp the vent pipe close to the collar and bend to 45° angle. Do not exceed 45°. Rise FP1473 corner flex install 4/04 djt FP1472 Fig. 20 There must be a 1/2” rise per foot length. FP1005 Fig. 18 Side view of final unit location.
LDVR Series Direct Vent Gas Fireplace Horizontal plane means no vertical rise exists on this portion of the vent assembly. • The maximum horizontal vent run is 20 ft. (6.1m) when the vertical vent rise is 7¹⁄₂ ft. (2.3m). (Fig. 21) • The maximum number of 90° elbows per side wall installation is three (3). Vertical Dimension 7¹⁄₂ʼ Minimum When Horizontal Run is 20ʼ 7 ft. (2134 mm) 10 ft. (3048 mm) Maximum 20 ft. (6.1m) 12" (305mm) 90° Elbow = 3 ft. A + B = 17 ft. (Max.) 7 ft. 6 in. (2286 mm) 48" (1.
LDVR Series Direct Vent Gas Fireplace Vertical Sidewall Installation STEP 1 Locate vent opening on the wall. It may be necessary to first position the fireplace and measure to obtain hole location. Depending on whether the wall is combustible or noncombustible, cut opening to size. (Fig. 25) Adjustable Zero Clearance Sleeve #8 Screws (2) #8 Screws (2) For combustible walls first frame in opening. Combustible Walls (Fig. 25): Cut a 9³⁄₈”H x 9³⁄₈” W (240 x 240mm) hole through the exterior wall and frame.
LDVR Series Direct Vent Gas Fireplace X X X Always install horizontal venting on a level plane. CFM138 CFM136 Fig. 28 Measure horizontal length including 2” overlap. CFM136 X length Rear Vent horizontal High 2/26/01 sta Temperature Sealant Fig. 30 Horizontal length requirement. CFM138 Below Grade 4", 7" collarInstallations 2/26/01 sta When it is not possible to meet the required vent terminal clearances of 12” (305mm) above grade level a snorkel vent kit #7TDVSNORK is required.
LDVR Series Direct Vent Gas Fireplace Zero Clearance Sleeve (if required) 7TDVSNORK (Snorkel) Firestop 4” (102mm) Clearance Min. 7” Pipe Vertical Through-the-Roof Applications This Gas Fireplace has been approved for: 1. Vertical installations up to 40ʼ (12 m) in height. Up to 10ʼ (3 m) horizontal vent run can be installed within the vent system using a maximum of three 90° elbows.
LDVR Series Direct Vent Gas Fireplace Attic Insulation Shield Max. 8ʼ (2.4m) 45° 40ʼ (12m) Max. 8ʼ (2.4m) Joist Typical Ceiling Support Application Ceiling Installation 45° 11" 11" Upper Floor Joist Typical Roof Support Application Typical Offset Installation Firestop Spacer Nails (4) FP1021 Fig. 34 Typical vertical roof applications. FP1021 Vertical Through-the-Roof Installation Typical vertical through the roof 1. Locate your fireplace. application 2.
LDVR Series Direct Vent Gas Fireplace Vent Termination Roof Storm Collar 2ʼ Min. Roof Flashing Roof Support Attic Insulation 40ʼ Shield (12m) Attic Insulation Joists Min. 2' (610 mm) Joists FP1185 Fig. 38 Minimum termination to roof clearance. FP1022 Fig. 37 Typical straight-up installation.
LDVR Series Direct Vent Gas Fireplace Venting Components 7TDVRVT - Through the wall Rear Vent Termination 584A venting components rear vent term 4/6/99 djt 584B Vent components Starter Kit 2/25/99 djt 584C Vent components 584D 45 degree elbow Vent Components 2/25/99 90 degree djt elbow 584E 10/20/99djttwistlock 2/25/99 Venting Components 10/20/99 twist lock Telescope vent 584F 2/25/99 djt Venting Components 10/20/99 twist lock Pipe sections 2/25/99 djt 10/20/99 twist lock 584G Venting Components Firest
LDVR Series Direct Vent Gas Fireplace Operating Instructions Glass Information • • • • Only glass approved by CFM Specialty Home Products should be used on this fireplace. The use of any non-approved replacement glass will void all product warranties. Care must be taken to avoid breakage of the glass. Do not operate appliance with glass front removed, cracked or broken.
LDVR Series Direct Vent Gas Fireplace Installation of Logs, Lava Rock & Ember Material The logs are fragile and should be handled with care. Keep the packaging material out of the reach of children and dispose of the material in a safe manner. The individual logs can be easily identified by the numbers cast on the underside of each log.
LDVR Series Direct Vent Gas Fireplace Rear (B135) Front Left (B136) 43LDVR Front Center (B138) Front Right (B137) LG383 Fig. 42 Correct log placement for 36LDVR. 39LDVR 1. Place rear lob (BC14) on rear bracket (ensure log is LG383 centered and seated properly to the log support). 36LDVR logshole to 2. Place front left log (BC15). Use logʼs bottom locate it onto the front support and just rest on top of 1/05 the rear log. 3. Place front right log (BC16).
LDVR Series Direct Vent Gas Fireplace Flame & Temperature Adjustment RN/RP & EN/EP Models For units equipped with “HI/LO” valves the flame adjustment is accomplished by rotating the “HI/LO” adjustment knob located near the center of the gas control valve. (Figs. 45 & 46) �� Turn counterclockwise to decrease flame height Honeywell Valve �� Turn clockwise to increase flame height Glowing Embers LG384 Fig. 48 Correct burner flame appearance for 33LDVR. Fig. 45 Flame adjustment knob for Honeywell valve.
LDVR Series Direct Vent Gas Fireplace Lighting and Operating Instructions FOR YOUR SAFETY READ BEFORE LIGHTING WARNING:If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This heater has a pilot which must be lit manually. When lighting the pilot follow these instructions exactly. B. BEFORE LIGHTING smell all around the heater area for gas.
LDVR Series Direct Vent Gas Fireplace Lighting and Operating Instructions For Fireplaces equipped with SIT822 Gas Valve (EN or EP) Warning:If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury and loss of life. FOR YOUR SAFETY READ THE FOLLOWING WARNINGS BEFORE LIGHTING THE APPLIANCE A. This fireplace is equipped with an ignition device which automatically lights the pilot. DO NOT try to light the pilot by hand. B.
LDVR Series Direct Vent Gas Fireplace Troubleshooting - Honeywell Millivolt Valve Remove Window Frame Assembly Before Service Work CHECK Gas Supply On NO ▼ START • Supply Line Hooked Up • Shutoff Valve Open YES • Lockout Has Engaged. Wait 60 Seconds And Try Again. Pilot Lights With Piezo Ignitor NO ▼ ▼ • • YES ▼ NO • • • • YES YES NO ▼ ▼ Pilot Lights Main Burner Depressing Piezo 1/8" Gap To Pilot Hood Needed.
LDVR Series Direct Vent Gas Fireplace Troubleshooting the Gas Control System SIT 822 Valve with Synetek Electronic Control Operating Diagram Normal Operation Abnormal Operation ON/OFF Switch Closed? 5 sec Inter-Trial Delay YES Safe Start Check On? NO YES 0 Sec Purge Ignition Trial: 30 sec Spark ON Pilot Valve ON.
LDVR Series Direct Vent Gas Fireplace A E B C IL FP OF O D OF FP IL OT O F FC107/108 Fig. 52 Nova SIT820 Gas Valve. FC108 FC107 SIT820 valve conversion SIT 10/03 regulator Regulator Cap conversion Conversion Screw 10/03 LO The conversion of this appliance from one gas to another must be carried out by an authorized service provider. 1. Disconnect power to the unit and shut off the gas supply. 2. Remove window frame assembly. 3. Carefully remove the logs & lava rock material. 4.
LDVR Series Direct Vent Gas Fireplace Burner and Burner Compartment Maintenance It is important to keep the burner and the burner compartment clean. At least once per year the logs and lava rock/ember material should be removed and the burner compartment vacuumed and wiped out. Remove and refit the logs as per the instructions in this manual. Always handle the logs with care as they are fragile and may also be hot if the fireplace has been in use.
LDVR Series Direct Vent Gas Fireplace 1 1 33LDVR 36LDVR 1b 1f 1a 1h 1a 1b 1c 1a 1g 43LDVR 1d 1d 1d 1e 39LDVR 1 2 14 12 3 11 9 7a,b 6a,b 18a,b 19a,b 15 16 13 17 8 LO HI 21 1b 1c 1c 1i 1g 1a 20 23 26 27 30 29 31 36 24 22 25 33 34 28 32 35 37 39 40 41 42 43 CFM Specialty Home Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
LDVR Series Direct Vent Gas Fireplace LDVR Ref. 1. 1a. 1b. 1c. 1d. 1e. 1f. 1g. 1h. 1i. 2a. 2b. 3. 4a. 4b. 5a. 5b. 6a. 6b. 7a. 7b. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18a. 18b. 19a. 19b. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33a. 33b. 34. 35. 36.
LDVR Series Direct Vent Gas Fireplace LDVR Ref. 37. 38. 39. 40. 41. 42. 43.
LDVR Series Direct Vent Gas Fireplace Optional Accessories Available Fan Kits Thermal Sensor Fan FK24 Fan Assembly This auxiliary fan system increases the efficiency of the circulation of the heated air. The FK24 fan kit allows variable speed control of the circulation fan and also incorporates a heat sensor in the circuit.
LDVR Series Direct Vent Gas Fireplace Wiring Instructions The fireplace, when installed, must be electrically connected and grounded in accordance with local codes or, in the absence of local codes, with the current CSA C22.1 Canadian Electric Code. Side Panel Back Panel Log Support For USA installations follow the local codes and the national electrical code ANSI/NFPA No. 70. Should this fan require servicing or repair the power supply must be disconnected.
LDVR Series Direct Vent Gas Fireplace Screen Door Kit Optional Trim Kits Louvre Accent Trim Appliance Model Polished Brass 33LDVR 36LDVR 39LDVR 43LDVR Antique Brass 33LDVR 36LDVR 39LDVR 43LDVR Rustic Bronze 33LDVR 36LDVR 39LDVR 43LDVR Pewter 33LDVR 36LDVR 39LDVR 43LDVR Main Louvre Kit Additional Louvre 33DVLMP 36DVLMP 39DVLMP 43DVLMP 33DVLAP 36DVLAP 39DVLAP 43DVLAP 33DVLMA 36DVLMA 39DVLMA 43DVLMA 33DVLAA 36DVLAA 39DVLAA 43DVLAA 33DVLMR 36DVLMR 39DVLMR 43DVLMR 33DVLAR 36DVLAR 39DVLAR 43DVLAR 33DVL
LDVR Series Direct Vent Gas Fireplace 38 10007317
LIMITED LIFETIME WARRANTY LDVR Series Direct Vent Gas Fireplace PRODUCT COVERED BY THIS WARRANTY All Vermont Castings gas stoves, gas inserts, and gas fireplaces, and all Majestic or Northern Flame brand gas fireplaces equipped with an Insta-Flame Ceramic Burner, or standard steel tube burner.
Efficiency Ratings Model 33LDVRRN 33LDVRRP 33LDVREN 33LDVREP 36LDVRRN 36LDVRRP 36LDVREN 36LDVREP 39LDVRRN 39LDVRRP 39LDVREN 39LDVREP 43LDVRRN 43LDVRRP 43LDVREN 43LDVREP EnerGuide Ratings Fireplace Efficiency (%) 62.6 62.6 72.7 72.7 57.5 57.5 63.6 63.6 50.2 50.2 54.2 54.2 54.3 54.3 58.3 58.3 Steady State (%) Fan-OFF Fan-ON 81 82 82 83 81 82 82 83 81 82 82 83 81 82 82 83 76 79 79 80 78 79 79 80 77 78 78 79 77 78 78 79 CFM Specialty Home Products 410 Admiral Blvd.