B.  Clearances to Combustibles
When selecting a location for the appliance it is important 
to consider the required clearances to walls. See Figure 
3.6 and Figure 3.7.
WARNING! Risk of Fire or Burns! Provide adequate 
clearance around air openings and for service access. 
Due to high temperatures, the appliance should be lo-
cated out of traffi c and away from furniture and draperies.
NOTICE: Illustrations refl ect typical installations and are 
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams 
are not drawn to scale. Actual installation could vary due 
to individual design preference.
Figure 3.6  Appliance Locations: ECHELON Single-Sided Models
Model A B C D E F G
ECHEL36IN
Inches 62-1/2 48-1/4 88-1/8
See 
Section 
10, Figure 
10.16 and 
10.17.
24-1/2 18-3/4 1
Millimeters 1588 1226 2238 622 476 25
ECHEL48IN
Inches 70-3/4 60-1/4 100-3/8 28-1/2 18-3/4 1
Millimeters 1797 1530 2550 724 476 25
ECHEL60IN
Inches 79-1/2 72-1/4 112-3/8 31-3/4 18-3/4 1
Millimeters 2019 1835 2854 807 476 25
ECHEL72IN
Inches 88 84-1/4 124-3/8 35-1/4 18-3/4 1
Millimeters 2235 2140 3159 895 476 25
It is important to follow the framing and fi nishing instruc-
tions step by step to ensure proper placement of fi replace 
in the surrounding framing/fi nishing materials. 
B
C
A
B
G
F
E
B
G
D
Refer to Section 10 for hearth, mantel and 
wall projection information.
If a HEAT-ZONE® will be installed, refer to 
Section 5.E for information. 
2 HEAT-ZONES = Add 4 IN. to dimension B
1 HEAT-ZONE = Add 2 IN. to dimension B
B