Installation Manual
25
Majestic • ECHEL36IN/STIN, ECHEL48IN/STIN, ECHEL60IN, ECHEL72IN Installation Manual • 2406-970 Rev. C • 1/17 
Figure 4.10
Top Vent - Horizontal Termination
Venting with 2 elbows
Note: Use DVP Series 
components only.
ECHEL36IN, ECHEL48IN
V
1
 Minimum H
1 
+ H
2
 Maximum
2 ft. 610 mm 1.5 ft. 457 mm
3 ft. 914 mm 6 ft. 1.8 m
4 ft. 1.2 m 9 ft. 2.7 m
5 ft. 1.5 m 12 ft. 3.7 m
6 ft. 1.8 m 15 ft. 4.6 m
7 ft. 2.1 m 18 ft. 5.5 m
8 ft. 2.4 m 21 ft. 6.4 m
V
1
 + H
1 
+ H
2
 = 63 ft. (19.2 m) Maximum
H
1
 + H
2
 = 40 ft. (12.2 m) Maximum
INSTALLED
HORIZONTALLY
H
2
H
1
V
1
ECHEL60IN, ECHEL72IN
V
1
 Minimum H
1 
+ H
2
 Maximum
3 ft. 914 mm 1-1/2ft. 457 mm
4 ft. 1.2 m 6 ft. 1.8 m
5 ft. 1.5 m 9 ft. 2.7 m
6 ft. 1.8 m 12 ft. 3.7 m
7 ft. 2.1 m 15 ft. 4.6 m
8 ft. 2.4 m 18 ft. 5.5 m
9 ft. 2.7 m 21 ft. 6.4 m
V
1
 + H
1 
+H
2
 = 63 ft. (19.2 m) Maximum
H
1
 + H
2
 = 40 ft. (12.2 m) Maximum
WARNING! Risk of Fire! 
DO NOT attach elbow directly to the appliance. 
• The ECHEL36IN, ECHEL48IN and ECHEL60IN require a minimum of 24 inches of vertical venting before attaching any 
elbow to the appliance.
• The ECHEL36STIN, ECHEL48STIN and ECHEL72IN require a minimum of 36 inches of vertical venting before attaching 
any elbow to the appliance.
ECHEL36STIN, ECHEL48STIN
V
1
 Minimum H
1 
+ H
2
 Maximum
3 ft. 914 mm 6 ft. 1.8 m
4 ft. 1.2 m 9 ft. 2.7 m
5 ft. 1.5 m 12 ft. 3.7 m
6 ft. 1.8 m 15 ft. 4.6 m
7 ft. 2.1 m 18 ft. 5.5 m
8 ft. 2.4 m 21 ft. 6.4 m
V
1
 + H
1 
+H
2
 = 63 ft. (19.2 m) Maximum
H
1
 + H
2
 = 40 ft. (12.2 m) Maximum