Exhaust restrictors are recommended for these vertically
terminated products which have excessive draft. Exhaust
restrictors will compensate for high draft, and restore vi-
sual ame height. If the vent con guration has a total ver-
tical of 20-50 feet, an exhaust restrictor may be needed.
The exhaust restrictor can be located in the appliance
manual bag.
Figure 4.13 Exhaust Restrictor
NOTICE: Before painting, contact your dealer for
information on the appropriate high temperature paint.
Exhaust restrictor: ECHEL36IN, ECHEL48IN,
ECHEL60IN, ECHEL72IN
1. Locate the two pilot holes in the inside rebox cham-
ber as shown in Figure 4.13.
2. Break the ue restrictor into two pieces. Do this by
bending the part back and forth until it breaks. See
Figure 4.14.
3. The setting for ECHEL36IN, ECHEL48IN, ECH-
EL60IN and ECHEL72IN is 2-2. Align the holes
marked “2” on the numbered exhaust restrictor piece
with the hole on the other exhaust restrictor piece.
See Figure 4.15. Align the exhaust restrictor pieces
with the pilot holes in the inner rebox chamber. Use
two 1/2 inch self-piercing screws to secure vent re-
strictor to rebox heat shield.
4. In some applications, such as those where the re-
place is elevated off the oor, the exhaust restrictor
may be painted, but painting is not required.
EXHAUST
RESTRICTOR
PILOT
HOLES
Figure 4.14 Break the Exhaust Restrictor
1 2 3 4 5
SETTING
1 2 3 4 5
BREAK
HERE
Exhaust restrictor Instructions
Figure 4.15 Set the Exhaust Restrictor
Exhaust restrictor: ECHEL36STIN, ECHEL48STIN
1. Break the ue restrictor into two pieces. Do this by
bending the part back and forth until it breaks. See
Figure 4.14.
Note: The ECHEL36STIN and ECHEL48STIN do not
have pilot holes for the exhaust restrictor in the rebox
chamber.
2. The setting for ECHEL36STIN and ECHEL48STIN is
a 2.5 inch setting, or 2-2. Align the holes marked
“2” on the numbered exhaust restrictor piece with the
hole on the other exhaust restrictor piece. See Fig-
ure 4.15. Center the exhaust restrictor on the vent
and secure in place with two 1/2 inch self-piercing
screws.
3. In some applications, such as those where the re-
place is elevated off the oor, the exhaust restrictor
may be painted, but painting is not required.
NOTICE: Before painting, contact your dealer for
information on the appropriate high temperature paint.