Installation Manual
29
Majestic • ECHEL36IN/STIN, ECHEL48IN/STIN, ECHEL60IN, ECHEL72IN Installation Manual • 2406-970 Rev. C • 1/17 
Figure 4.16
Top Vent - Vertical Termination
Venting with 2 elbows
ECHEL36IN, ECHEL48IN, ECHEL60IN
V
1
 + V
2 
Minimum H
Maximum
2 ft. 610 mm 4 ft. 1.2 m
3 ft. 914 mm 9 ft. 2.7 m
4 ft. 1.2 m 12 ft. 3.6 m
5 ft. 1.5 m 15 ft. 4.5 m
V
1
 + H
1 
+ V
2
 = 63 ft. (19.2 m) Maximum
H
Total
 = 23 ft. (7.1 m) Maximum
H
1
V
2
V
1
ECHEL72IN 
V
1
 + V
2 
Minimum H
Maximum
3 ft. 914 mm 4 ft. 1.2 m
4 ft. 1.2 m 9 ft. 2.7 m
5 ft. 1.5 m 12 ft. 3.6 m
6 ft. 1.8 m 15 ft. 4.5 m
V
1
 + H
1 
+ V
2
 = 63 ft. (19.2 m) Maximum
H
Total
 = 23 ft. (7.1 m) Maximum
Note: Use DVP Series 
components only.
WARNING! Risk of Fire! 
DO NOT attach elbow directly to the appliance. 
• The ECHEL36IN, ECHEL48IN and ECHEL60IN require a minimum of 24 inches of vertical venting before attaching any 
elbow to the appliance.
• The ECHEL36STIN, ECHEL48STIN and ECHEL72IN require a minimum of 36 inches of vertical venting before attaching 
any elbow to the appliance.
 ECHEL36STIN, ECHEL48STIN
V
1
 + V
2 
Minimum H
Maximum
3 ft. 914 mm 9 ft. 2.7 m
4 ft. 1.2 m 12 ft. 3.6 m
5 ft. 1.5 m 15 ft. 4.5 m
V
1
 + H
1 
+ V
2
 = 63 ft. (19.2 m) Maximum
H
Total
 = 23 ft. (7.1 m) Maximum










