Installation Manual
44
Majestic • ECHEL36IN/STIN, ECHEL48IN/STIN, ECHEL60IN, ECHEL72IN Installation Manual • 2406-970 Rev. C • 1/17
Accessories Requirements
• This appliance ships standard with a remote control.
Wiring for optional Hearth & Home Technologies approved
accessories should be done now to avoid reconstruction.
Follow instructions that come with those accessories.
The junction box, control module, LED power supply
and wall switch receiver can be accessed by removing
the bottom glass shield and component heat shield.
The decorative front must be removed to access these
components. See Figure 8.3.
IntelliFire™ Plus Ignition System Wiring
• Wire the appliance junction box to 110-120 VAC for
proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.
• Refer to Figure 8.4, IPI Wiring Diagram.
• This appliance is equipped with an IntelliFire™ Plus
control valve which operates on a 6 volt/1.5 AMP system.
• Plug the 6 volt transformer plug into the appliance junction
box to supply power to the unit OR install 4 AA cell
batteries (not included) into the battery pack before use.
B. Wiring Requirements
NOTICE: Batteries should only be used as a power source
in the event of an emergency power outage. Batteries
should not be used as a primary long-term power source.
Battery polarity must be correct when installing batteries.
When using batteries as a power source, the 6-volt
transformer must be unplugged from the receptacle.
Do not store batteries in the battery pack when the
appliance is powered by the 6 volt transformer connected
to permanent electrical service.
Figure 8.4 IntelliFire™ Plus Wiring Diagram with Remote
CAUTION! Risk of Overheating! Component heat shield
MUST be installed before operating appliance. Electrical
components will be damaged.
NOTICE: When installing the power vent with the Echelon
models, the LED will need to be disconnected from the
AUX2 (factory setting) and moved to AUX1. Plug the
power vent system into AUX2. The LED function will only
be operational on the HIGH setting.
LED LIGHT TRAY
TO JUNCTION
BOX (110V)
MODULE
I
S
FLAME
SENSE
IGNITER
RC300 4.5V DC
(AAA X 3)
TO JUNCTION
BOX 110VAC
ORANGE
(PILOT)
GREEN
(MAIN)
FLAME
MODULATION
AUX300 MODULE
AUX 1
AUX 2
FAN
GROUND
BROWN
BLACK
RED
BATTERY PACK
6V DC
LED CONTROL