0-4 Inch Thickness-Inside Fit Method
0-4 Inches Finishing (Inside Fit):
See Figure 10.10 the required measurements to ensure 
hte proper fi t of the PFF. The top and bottom will have a 
1/2 inch space from the PFF to the fi nished wall above 
and below it. This is required to prevent the appliance 
from overheating. 
WARNING! Risk of Fire! DO NOT apply combustible 
materials beyond the minimum clearances. Comply with 
all minimum clearances to combustibles as specifi ed  in 
this manual. Overlapping materials could ignite.
Figure 10.10 Minimum Finished Opening Dimensions - Picture Frame Front - Inside Fit 0-4 Inch
24-3/8 IN.
ECHEL36 = 47-1/4 IN.
ECHEL48 = 59-1/4 IN.
ECHEL60 = 71-1/4 IN.
4-7/16 IN.
4-7/16 IN.
4-1/8 IN.
4-1/2 IN.
1/2 IN. (TOP & BOTTOM) BETWEEN FINISHING MATERIAL
& PFF SURROUND FOR AIR FLOW
1/2 IN. 
RECTANGULAR ACCESS HOLES COVERED
1/2 IN. (TOP & BOTTOM) BETWEEN FINISHING MATERIAL
& PFF SURROUND FOR AIR FLOW