C.  Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as specifi ed. Framing closer than the 
minimums listed must be constructed entirely of noncom-
bustible materials (i.e., steel studs, concrete board, etc.) 
Combustible Mantels
Note: For non-combustible fi replace fi nish material (marble, 
stone, etc) specifi cations refer to Section 10.A.
Figure 10.12  Minimum Vertical and Maximum Horizontal 
  Dimensions of Combustibles - ECHEL36IN and 
 ECHEL48IN
MEASUREMENT FROM
TOP EDGE OPENING
18
20
23
26
29
31
TO CEILING
9
12
6
3
1
Measurement from top edge opening 
to bottom of appliance = 24-1/2 IN.
MAX.
Note: All measurements in inches.
MEASUREMENT FROM
TOP EDGE OPENING
24
27
30
31
TO CEILING
9
6
3
Measurement from top edge opening 
to bottom of appliance = 24-1/2 IN.
MAX.
Figure 10.13  Minimum Vertical and Maximum Horizontal 
  Dimensions of Combustibles - ECHEL60IN and 
 ECHEL72IN
Note: All measurements in inches.
TOP OF APPLIANCE OPENING
Figure 10.11 Location of Appliance Opening