Installation Manual
7
Majestic • ECHEL36IN/STIN, ECHEL48IN/STIN, ECHEL60IN, ECHEL72IN Installation Manual • 2406-970 Rev. C • 1/17 
2 
2 
Getting Started 
Installation and service of this appliance should be 
performed by qualifi ed personnel. Hearth & Home 
Technologies suggests NFI certifi ed or factory 
trained professionals, or technicians supervised by 
an NFI certifi ed professional (www.nfi certifi ed.org).
A.  Design and Installation Considerations
Majestic direct vent gas appliances are designed to oper-
ate with all combustion air siphoned from outside of the 
building and all exhaust gases expelled to the outside. No 
additional outside air source is required.
Installation MUST comply with local, regional, state and 
national codes and regulations. Consult insurance carrier, 
local building inspector, fi re offi cials or authorities having 
jurisdiction over restrictions, installation inspection and 
permits.
Before installing, determine the following:
•  Where the appliance is to be installed.
•  The vent system confi guration to be used.
•  Gas supply piping.
•  Electrical wiring requirements.
• Framing and fi nishing details.
•  Whether optional accessories—devices such as a wall 
switch or remote control—are desired.
Improper installation, adjustment, alteration, service or 
maintenance can cause injury or property damage. For 
assistance or additional information, consult a qualifi ed 
service technician, service agency or your dealer.
Figure 2.1 Good Faith Wall Surface Temperatures Above Appliance
(ECHEL36IN, ECHEL36STIN, ECHEL48IN, ECHEL48STIN)
B. Good Faith Wall Surface/TV Guidelines
NOTICE:  Temperatures listed above are taken with a 
temperature measuring probe as prescribed by the test 
standard used for appliance certifi cation.  Temperatures 
on walls or mantels taken with an infrared thermometer 
may yield increased temperatures of up to 30 degrees or 
more depending on the thermometer settings and material 
characteristics being measured.
MEASUREMENTS FROM
TOP EDGE OF THE OPENING
6 in.
18 in.
24 in.
30 in.
36 in.
48 in.
TO CEILING
42 in.
12 in.
170°F
APPLIANCE FRONT
155°F
145°F
140°F
130°F
125°F
125°F
Figure 2.2. Good Faith Wall Surface Temperatures Above Appliance 
(ECHEL60IN, ECHEL72IN)
MEASUREMENTS FROM
TOP EDGE OF THE OPENING
6 in.
18 in.
24 in.
30 in.
36 in.
48 in.
TO CEILING
42 in.
12 in.
245°F
APPLIANCE FRONT
190°F
155°F
140°F
135°F
125°F
125°F