Installation Manuel

Majestic Sovereign Series • SA36/SA42C • Installers Manual • 4010-262 • Rev E • 07/19/16
15
6 ft (1.83 m) max.
unsupported chimney
above roof
20 ft (6.10 m) max.
pipe between an
offset & return
35 ft (10.7 m)
max. straight
unsupported
chimney height
16.5 ft (5.03 m) min. height/single offset-return
20 ft. (6.10 m) min. height/double offset-return
90 ft (27.4 m) max. height
41-3/8 in.
(1051 mm)
Effective
Height
Ceiling firestop
Figure 4.1 Chimney Requirements
NOTICE: A maximum of two pairs of offsets and returns
may be used.
Minimum overall straight height 16.5 ft 5.03 m
Minimum height with single offset/
return
16.5 ft 45.03 m
Double offset/return minimum height 20ft 6.1 m
Maximum height 90 ft 27.43m
Maximum chimney length between an
offset and return
20ft 6.1 m
Maximum distance between chimney
stabilizers
35 ft 10.67m
Maximum unsupported chimney
length between the offset and return
6 ft 1.83 m
Maximum unsupported chimney
heightabovethereplace
35 ft 10.67m
Maximum unsupported chimney
above roof
6 ft 1.83 m
NOTICE: You must provide support for the pipe during
construction and check to be sure inadvertent loading has
notdislodgedthechimneysectionfromthereplaceorat
any chimney joint.
A. Chimney Requirements
Vertical distances are measured from the base of the
replace as shown in Figure 4.1.
4
Chimney and Termination Requirements
Table 4.2 Chimney Component Dimensions
Table 4.1 Chimney Requirements
WARNING! Risk of Fire! You must maintain 2
in. (51 mm) air space clearance to insulation
and other combustible materials around the
chimney system. Failure to do so may cause
overheating and re.
HEIGHT OF CHIMNEY COMPONENTS in. mm
Chimney Stabilizer
SL3 4-3/4 121
Offsets/Returns
SL315 13-3/8 340
SL330 15-1/2 394
Chimney Sections*
SL306 4-3/4 121
SL312 10-3/4 273
SL318 16-3/4 425
SL324 22-3/4 578
SL336 34-3/4 883
SL348 46-3/4 1187
* Dimensions reect effective height.