6 ft (1.83 m) max.
unsupported chimney
above roof
20 ft (6.10 m) max.
pipe between an
offset & return
35 ft (10.7 m)
max. straight
unsupported
chimney height
16.5 ft (5.03 m) min. height/single offset-return
20 ft. (6.10 m) min. height/double offset-return
90 ft (27.4 m) max. height
41-3/8 in.
(1051 mm)
Effective
Height
Ceiling firestop
Figure 4.1 Chimney Requirements
NOTICE: A maximum of two pairs of offsets and returns
may be used.
Minimum overall straight height 16.5 ft 5.03 m
Minimum height with single offset/
return
16.5 ft 45.03 m
Double offset/return minimum height 20ft 6.1 m
Maximum height 90 ft 27.43m
Maximum chimney length between an
offset and return
20ft 6.1 m
Maximum distance between chimney
stabilizers
35 ft 10.67m
Maximum unsupported chimney
length between the offset and return
6 ft 1.83 m
Maximum unsupported chimney
heightabovethereplace
35 ft 10.67m
Maximum unsupported chimney
above roof
6 ft 1.83 m
NOTICE: You must provide support for the pipe during
construction and check to be sure inadvertent loading has
notdislodgedthechimneysectionfromthereplaceorat
any chimney joint.
A. Chimney Requirements
Vertical distances are measured from the base of the
replace as shown in Figure 4.1.
4
Chimney and Termination Requirements
Table 4.2 Chimney Component Dimensions
Table 4.1 Chimney Requirements
WARNING! Risk of Fire! You must maintain 2
in. (51 mm) air space clearance to insulation
and other combustible materials around the
chimney system. Failure to do so may cause
overheating and re.
HEIGHT OF CHIMNEY COMPONENTS in. mm
Chimney Stabilizer
SL3 4-3/4 121
Offsets/Returns
SL315 13-3/8 340
SL330 15-1/2 394
Chimney Sections*
SL306 4-3/4 121
SL312 10-3/4 273
SL318 16-3/4 425
SL324 22-3/4 578
SL336 34-3/4 883
SL348 46-3/4 1187
* Dimensions reect effective height.