Installation Manuel

Majestic Sovereign Series • SA36/SA42C • Installers Manual • 4010-262 • Rev E • 07/19/16
33
B
A
12 in.
[305 mm]
9 3/4 in.
[248 mm]
12 in.
[305 mm]
10 3/4 in.
[273 mm]
FLUSH
FRONT
4 in.
[102 mm]
BRICK
FRONT
50° angle
39° angle
Grid represents 1 in. scale
A
Fireplace
Opening
B
Outside
Dimensions
in.
36 42
mm
914 1067
in.
42 48
mm
1067 1219
SA36
SA42
Model #
Figure 7.13 Mantel Leg, Surround or Wall Projection (acceptable on both sides of opening)
E. Sidewalls/Surrounds
Locate adjacent combustible sidewalls a minimum of 12
in. (305 mm) from replace opening.
Mantle leg, surround, stub wall, whether combustible
or non-combustible, may be constructed as shown in
Figure 7.13.