Installation Manuel

Majestic Sovereign Series • SA36/SA42C • Installers Manual • 4010-262 • Rev E • 07/19/16
6
F
E
D
B
C
Across a
corner
G
As a
room
divider
A
48 in.
(1219 mm)
minimum
B
Along a wall
B
A
1/2 in. (13 mm) all
configurations
G
3/4 in. (19 mm) min. air
space from fireplace to
combustible materials. 1/2
in. (13 mm) allowed at
nailing flanges.
Note:
G
A*
In an exterior chase
or projecting into a
garage
B
Note: Measurements are FRAMING dimensions only and do
not include drywall either in the cavity or on the interior walls.
H
H
H
*
8 in. (203 mm) extra space
included for outside air
connection. If outside air duct
has no bend, this dimension
may be reduced as long as
minimum clearances are met.
Model # A B C D E F G H
in.
51 43 74 7/8 35 3/4 15 3/4 53 23
mm
1295 1092 1902 908 400 1346 584
in.
57 49 77 1/2 38 7/8 18 54 7/8 23
mm
1448 1245 1969 987 457 1394 584
SA36
SA42
12 in. (305 mm)
Minimum from FP
opening to any
perpendicular wall.
Figure 2.2 Fireplace Locations
NOTICE:
• Illustrationsandphotosreecttypicalinstallationsand
are FOR DESIGN PURPOSES ONLY.
Illustrations/diagrams are not drawn to scale.
Actual installation/appearance may vary due to individual
design preference.
Hearth & Home Technologies reserves the right to alter
its products.
NOTICE: In addition to these framing dimensions, also
reference the following section: Clearances (Section 3).
NOTICE:
A minimum 3/4 in. (19 mm) air clearance at the
backandsidesofthereplaceassemblymustbe
maintained.
Chimney sections at any level require
a 2 in. minimum air space clearance
between the framing and chimney sec-
tions.
B. Design and Installation Considerations
NOTICE: Check building codes prior to installation.
Installation MUST comply with local, regional, state and
national codes and regulations.
Consult insurance carrier, local building inspector, re
ofcials or authorities having jurisdiction over restrictions,
installation inspection and permits.
Before installing, determine the following:
- Where the replace is to be installed.
- The vent system conguration to be used.
- Gas supply piping.
- Electrical wiring.
- Framing and nishing details.
- Whether optional accessories - devices such as a
fan, wall switch or remote control - are desired.
1. Selecting Fireplace Locations
This replace may be used as a room divider, installed
along a wall, across a corner or used in an exterior chase.
See Figure 2.2.
Locating the replace in a basement should be avoided.
Locating near frequently opened doors, central heat
outlets or returns, or other locations of considerable air
movement can affect the performance.
Consideration should be given to these factors before
deciding on a location.