2. Locating Fireplace & Chimney
Location of the replace and chimney will affect perfor-
mance.
Install within the warm airspace enclosed by the building
envelope. This helps to produce more draft, especially
during lighting and die-down of the re.
Installing the replace in a basement is not recommended.
Penetrate the highest part of the roof. This minimizes
the effects of wind loading.
Locate termination cap away from trees, adjacent
structures, uneven roof lines and other obstructions.
Minimize the use of chimney offsets.
Consider the replace location relative to oor and ceiling
and attic joists.
Take into consideration the termination requirements in
Sections 4 and 5.
Marginal Location:
Below peak
Location NOT recommended:
Not the highest point of the roof
Wind loading possible
Multi-level Roofs
Windward
Leeward
Recommended Location:
Above peak
Recommended:
Insulated exterior chase
in cooler climates
Recommended Location:
Above peak
Inside heated space
Location NOT recommended:
Too close to tree
Below adjacent structure
Lower roof line
Avoid outside wall
Marginal Location:
Wind loading possible
Not recommended in basement due
to high negative pressure concerns
that effect draft
Figure 2.3 Recommended Chimney Locations
Install the outside air kit with the intake facing prevailing
winds during the heating season.
Ensure adequate outdoor air for all combustion
appliances and exhaust equipment.
Ensure furnace and air conditioning return vents are not
located in the immediate vicinity of the replace.
Avoid installing the replace near doors, walkways or
small isolated spaces.
Recessed lighting should be a “sealed can” design.
Attic hatches weather stripped or sealed.
Attic mounted duct work and air handler joints and seams
taped or sealed.