Owner's manual

Pitch Shift
1C. Temphonic LEDs: indicate mechanics of the pitch-shifting machine.
2C. Pitch Panel Control: bipolar panel control. At 50% no pitch shift, greater than 50% shifts pitch UP and
less than 50% shifts pitch DOWN. Range is ALWAYS dependent upon DEPTH setting.
3C. Pitch Trim (see calibration procedure)
4C. DEPTH Panel Control: unipolar panel control that sets the index of the pitch shift, ranging from sub-mi
crotonal chorusing to 4 octaves harmonizing.
5C. PITCH 1 CV Attenuator: bipolar attenuator for PITCH 1 CV IN.
6C. DEPTH CV Attenuator: unipolar attenuator for DEPTH CV IN.
7C. DEPTH CV IN: unipolar control signal input. Range 0V to +5V.
8C. PITCH 1 CV IN: bipolar control signal input. Range +/- 4V.
9C. PITCH 2 CV IN: bi-polar control signal input. Range +/- 2V for total of 4 octave range. Set Pitch Panel
Control to full CCW for uni-polar control such as analog sequencer, or to 50% for bi-polar
control signal such as CV Keyboard.
1C
3C
2C
3A
4C
5C
6C
7C
8C
9C