User manual

20
Program Edit: Run / Stop
Run/Stop
Button-5 = Red
Run/Stop All
Button-5 = Blue
Alt Run/Stop
Button-5 = Purple
The Run/Stop Functions allows for modulating the phase relationship, resting, and re-setting the Variable Clock Outputs. When
set to Run, the Variable Clock Outputs operate as Programmed. When set to Stop, the Variable Clock Outputs are resting at 0V,
or O.
There are several types of Run/Stop behaviors to choose from that are Programmed using Button-5 in the Program Edit Page
(Double Press PGM_B):
Run/Stop Button-5 = Red
Run/Stop makes Mod Enabled Channels Run when a signal at the Mod Gate Input goes High and Stop when the Mod Gate Input signal
goes Low. The Mod LED is on when the Mod Gate is High and is o when it is Low. Run starts the channel immediately, regardless of
phase relationship to the Leading Tempo and preserves that Phase Oset until there is a State change or a Stop (ie. Mod Gate Low). This
allows for external modulation of a Channel's Phase relationaship to the Leading Tempo. Mod Disabled Channels are not aected. If a
signal patched to the Mod Input is an integer of the Leading Tempo (e.g. 1/1, 1/2, 1/4, 2/1...), Run/ Stop may also be used to Reset a
Channel.
Run/Stop All (a.k.a. James Cigler Mode) Button-5 = Blue
Makes all Channels Run on when a signal at the Mod Gate Input goes High and Stop when the Mod Gate Input signal goes Low, reseting
all CHannels on Run. The Mod LED is on when the Mod Gate signal is High and is o when it is Low. Mod Enabled Channels start
immediately regardless of phase relationship to the Leading Tempo, preserving that Phase Oset until there is State change or a Stop
(i.e. Mod Gate Low). Mod Disabled Channels start in Phase with the Leading Tempo. This behavior is nice for creating compositional
structures where you would like a Beginning or End. If synchronizing the TEMPI to DAW project, with the sync clock running, include 2
bars of silence at the beginning of composition so that TEMPI is locked into sync when it rst receives the Run signal at the Mod Input.
Run/ Stop All is also nice when used with a MIDI to CV module to convert MIDI Note On/Note O messages to Gate signals that may be
used to drive the TEMPI.
Alt Run/Stop (a.k.a. Robert A.A. Lowe Mode) Button-5 = Purple
Alt Run/Stop makes Mod Enabled Channels Run when a signal at the Mod Gate Input goes High and Stop when the Mod Gate Input
signal goes Low. Mod Disabled Channels have the inverse behavior, Stopping when the Mod Gate Input is High and Running when the
Mod Gate Input is Low. The Mod LED is on when the Mod Gate signal is High and is o when it is Low. Channels start immediately,
regardless of their phase relationship to the Leading Tempo, preserving their Phase Oset until there is a State change or a Stop (i.e. Mod
Gate Low). This allows for external modulation of a Channel's Phase relationaship to the Leading Tempo. If a signal patched to Mod
Input is an integer of the Leading Tempo (e.g. 1/1, 1/2, 1/4, 2/1...), it may also be used to Reset a Channel while maintaining Phase with
Leading Tempo.
Run/Stop O