TEMPI stores up to (64) timing scenarios referred to as States arranged into (4) Banks of (16). The State LED indicates Bank by color
and a change in State by ashing.
State is selected by either State Select CV or Select Gate, with State Select CV having top priority. The State Select Gate increments
the State value at the Rising edge of each Gate. In other words, when a State change is read at State Select CV, that change is
absolute and takes priority over State Select Gate changes.
There is a Gate Input for State Select Gate and a Combo Pot/CV Input for State Select CV. With nothing patched to State Select CV
Input, the State Select CV Combo Pot operates as a Panel Control which manually selects the State. The State Select CV Range is
0V to 5V.
To Reset to State 1, patch a Gate to the State Select CV Input and set the Combo Pot/attenuator so at Gate High, TEMPI goes to the
last State you would like to use (e.g. State 8). Next, patch a Clock or Gate to the State Select Gate Input and step through States 1
through 8. Send a Reset Gate with a short duty cycle to the State Select CV Input and at Gate Low, you will return to State 1. In
this way, it is possible to sequence any number of States linearly from State 1 to State n before Resetting.
Note: while on the Mute, Mod, Human, Machine, or Phase Programming Pages, State does not reect State Select changes via
CV or Gate until the active Programming Page is exited or completed. This behavior may be used creatively in order to manually
"freeze" the Mod functionality or State Select modulation. Also, if both Shift and Run/Stop are both enabled, all State selection
must be done using the State Select CV and Combo Pot, as the State Select Gate is used to Shift values.
State Edit : States
[Hold] PGM_A + PGM_B
or
+
Note: State Edit settings are saved on State Store.
[Press] Button-3
to Recall current Bank from Memory
[Press] Button-2
to Store current State
or
[Press] Button-1
to Recall current State
To Store or Recall a State